PLC Model Selection
Select Panasonic FP Series.
Applicable Devices
Note
(1) The maximum values that can be set by the PT are given.
(2) The addressable memory ranges depend on the model of PLC that is
used. Refer to the user manuals for your PLC for details.
Communications Settings
The following communications settings are recommended for the PT and
PLC.
■
PT Communications Settings (Set from the NV-Designer using the NV
Configuration.)
■
PLC Communications Settings
Note
With the FP2 CCU, the parity check is always odd and there is al-
ways one stop bit.
Bit/word devices
No.
Comments
Bit devices
Input relays
X 0000 to X 511F
Output relays
Y 0000 to Y 511F
Internal relays
R 0000 to R 886F
Link relays
L 0000 to L 639F
Timers
T 0000 to T 3071
Counters
C 0000 to C 3071
Special internal relays
R 9000 to R 910F
Word devices
Input relays
WX 0000 to WX 511
Output relays
WY 0000 to WY 511
Internal relays
WR 0000 to WR 886
Link relays
WL 0000 to WL 639
Data registers
DT 00000 to DT 10239
Link data registers
LD 0000 to LD 8447
Timer/counter set value area
SV 0000 to SV 3071
Timer/counter elapsed value area
EV 0000 to EV 3071
File registers
FL 00000 to FL 32764
Special data registers
DT 90000 to DT 90511
Item
Setting
Baud rate
19,200 bps
Data bits
8
Stop bits
1
Parity
Enabled, odd
Item
Setting
Communications mode
Computer link
Baud rate
19,200 bps
Data bits
8
Stop bits
1
Parity
Enabled, odd
End code
CR
Start code
No STX
Unit number
1
Modem connection
No connection
Summary of Contents for NV3Q Series
Page 1: ...Cat No V105 E1 02 Programmable Terminals NV Series NV3W NV4W NV3Q HOST CONNECTION MANUAL ...
Page 2: ......
Page 3: ...NV Series NV3W NV4W NV3Q Programmable Terminals Produced December 2009 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 16: ...xvi ...
Page 20: ...xx ...
Page 68: ...44 S7 200 Series Section 5 1 ...
Page 69: ...45 SECTION 6 Connecting to LG PLCs 6 1 MASKER K Cnet Series 46 6 1 1 Connection Method 46 ...
Page 72: ...48 MASKER K Cnet Series Section 6 1 ...
Page 76: ...52 FA M3 Series Section 7 1 ...
Page 110: ...86 Web Controller Series Section 9 3 ...
Page 120: ...96 Modbus RTU Mode Temperature Controller Section 10 3 ...
Page 142: ...118 Modbus Connections Section 12 5 ...
Page 144: ...120 Revision History ...