![background image](http://html.mh-extra.com/html/omron/nt21/nt21_setup-manual_744541208.webp)
199
Appendix E
Making the Cable for Connecting a Personal
Computer
Refer to the following when making a cable for connecting the NT Support Tool.
Assembly of Connecting Cables
Wiring should be carried out in one of the following ways, depending on the type of RS-232C connector.
25-pin Connector
SD
RD
RS
CS
SG
FG
Personal computer
Connector for peripheral devices on PT
Shield
Connector hood
2
3
4
5
7
1
SD
RD
RS
CS
SG
+5 V
2
3
4
5
9
6
Connector hood
Use the following recommended products when making the connecting cable.
Name
Model
Remarks
Connector
XM2D-2501
25-pin, made by OMRON, for personal computer side
XM2A-0901
9-pin, made by OMRON, for PT side
Connector hood
XM2S-2511
25-pin, made by OMRON, for personal computer side
XM2S-0911
9-pin, made by OMRON, for PT side
Connector set
XM2S-0911-S003
9-pin, made by OMRON, for PT side
Connector and Connector hood
Cable
AWG28
5P IFVV-SB
Multi-core shielded cable, made by Fujikura Ltd.
CO-MA-VV-SB 5P
28AWG
Multi-core shielded cable, made by Hitachi Cable, Ltd.