Do not turn OFF the power supply to the PT while downloading or up-
loading screen data or system programming. The screen data and
system programming may become corrupted.

Secure the PT's cable at the control panel when connecting it to the control panel. 

Be sure not to trip over the cable when moving around while holding the PT. 

Use safety circuits that are capable of detecting shorts in the emer-
gency stop switch and enable switch.

When using the NSH5, use the lefthand belt or use a commercially avail-
able neck strap. If the NSH5 falls, injury or device damage may occur. 

Periodically inspect for loose cables or other cable problems.

Confirm the safety of the system before turning ON or OFF the power
supply or before pressing the reset button.

After changing the settings of the DIP switch, always turn the power
supply OFF and ON or reset the PT.

Do not operate a touch switch using a screwdriver or other tool.

To ensure safety when using numeral input functions, set the upper and
lower limits for the input value.

Dispose of any battery that has been dropped on the floor or otherwise
subjected to excessive shock. The battery may leak if it is used.

Commercially available USB hubs and the recommended USB hub do
not necessarily have the same general specifications as the NSH5, and
may not function properly if used in environments subject to static elec-
tricity or other forms of noise. When using a USB hub, take sufficient
measures to prevent static electricity and other forms of noise, or do
not install the PT in an environment subject to such noise.

Do not disassemble or short-circuit the battery.

The backlight in the PT cannot be replaced by the user. Contact your
OMRON representative for backlight replacement.

Periodically check the installation conditions in applications where the
PT is subject to contact with oil or water.

Water and oil resistance will be lost if the front sheet is torn or is peel-
ing off. Do not use the PT if the front sheet is torn or is peeling off.

The Rubber Packing will deteriorate, shrink, expand, or harden depending on
the operating environment. Inspect and replace the Rubber Packing periodically. 

If the brightness of the backlight on the PT is reduced, the display and RUN in-
dicator may be very dark. Do not reduce the brightness of the backlight so far
that the display and RUN indicator cannot be seen. (This applies to lot numbers 
3073 and later.) 

Operating Environment Precautions 

Do not install the PT in any of the following locations:

⋅ 

Locations subject to rapid changes in temperature

⋅ 

Locations subject to temperatures or humidity outside the range

specified in the specifications 

⋅ 

Locations subject to condensation as a result of high humidity

⋅ 

Locations subject to splashing chemicals or solvents

⋅ 

Locations subject to oil splashes

⋅ 

Locations subject to corrosive or flammable gases

⋅ 

Locations subject to strong shock or vibration

⋅ 

Locations outdoors subject to direct wind and rain

⋅ 

Locations subject to strong ultraviolet light

⋅ 

Locations subject to dust

⋅ 

Locations subject to direct sunlight

Take appropriate and sufficient countermeasures when installing sys-
tems in the following locations:

⋅ 

Locations subject to static electricity or other forms of noise

⋅ 

Locations subject to strong electromagnetic or magnetic fields

⋅ 

Locations close to power supply lines

⋅ 

Locations subject to possible exposure to radioactivity

„

Compliance with 

(8

 Directives

1. This product is EMC compliant when assembled in a complete

PLC system of the specified PLC Series. Refer to the applicable
manual for grounding, cable selection, and any other conditions
for EMC compliance.

NSH5-Series Hand-held Programmable Terminal Operation
Manual

 (Cat. No. V090)

2. This is a class A product. It may cause radio interference in resi-

dential areas, in which case the user may be required to take
adequate measures to reduce interference.

„

Special Cable Specifications

The following table lists the Loose-wire/D-Sub and UL-standard Spe-
cial Cable models. Cables are provided for both RS-232C and
RS-422A depending on the serial communications protocol. 

Cable type

Communi-

cations 

connector

Serial 

commu-

nications 

Model 

Length

NSH5-232CW-3M 3 

RS-232C 

NSH5-232CW-10M 10 

Loose-wire
/D-Sub 

9-pin D-Sub 
+ Loose 
wires 

RS-422A NSH5-422CW-10M  10 

NSH5-232UL-3M 3 

Loose  
wires + 
relay cable 

RS-232C 

NSH5-232UL-10M 10 

UL 
Standard 

Loose wires

RS-422A 

NSH5-422UL-10M 

10 m 

Note (1): The Special Cable is sold separately. 

(2): Always use a UL-standard cable for applications requiring UL 

certification.  

„

Cable Dimensions

UL-standard Models (RS-232C) 

NSH5....

CN1

CN2

CN3

7L30 dia.

P4/7

CN6

232C Relay cable

7L30 dia.

CN5

CN8

CN4

CN7

7L30 dia.

Loopback connector

Loopback connector

21 22

23

7

8

9

10

26

24

25

19 20

NSH5-232UL-3M/10M

70

±

10

L

(30)

±

30

(30)

1,000

80

±

10

300

±

10

(30)

200

±

10

When connecting to an OMRON PLC, the control signals must be looped back.  
Connect loopback connectors to CN8 and CN7.

18

17

20

19

16

15

12

11

21 22

13 14

1

2

3

4

5

6

UL-standard Models (RS-422A) 

CN1

CN2

CN3

CN4

NSH5-422UL-10M

Shorted by 

connector 

(30) 

(30)

(30) 

80

±

10

70

±

10

300

±

10

7L30 dia.

NSH5

⋅⋅⋅

 

⋅⋅⋅⋅

⋅⋅⋅

⋅⋅⋅

⋅⋅

 

⋅⋅⋅⋅

⋅⋅⋅

⋅⋅⋅

⋅⋅

Loose-wire/D-Sub Cable 

G

70

+5

0

35

10,000

80

+5

0

H

I

AB

CD

EF

J

35

G

300

+15

0

No.1

100

+10

0

CN1

CN2

CN3

CN4

+300

300

K

L

1

CN

3

No.6

No.5

No.10

„

Connecting the Special Cable

z

 

Check before Connecting 

1.

Waterproof cable clamps are attached to both ends of the Special
Cable. The cable has inner and outer waterproof packing. The
packing is important to maintain the cables waterproof capabilities,
so be sure it is not lost or damaged.

NSH5 PT Cable Clamp

Cable attachment

FDS

 

Cable

SDFNLQJ

   Unit lock

housing

Heat-shrinking

WXEH

 

Packing

2.

Be sure the cable clamp housing is not damaged or dirty before
inserting it into the PT. If the housing is damaged, have it repaired
to retain the waterproof capabilities.

„

„

„

Operating Temperature

0 to 40

°

C

6XUURXQGLQJ$LU7HPSHUDWXUH±

$YRLGIUHH]LQJRUFRQGHQVDWLRQ

6XUURXQGLQJ$LU+XPLGLW\0D[

,QGRRUXVHRQO\

$OWLWXGH0D[P

,QVWDOODWLRQHQYLURQPHQW2YHU9ROWDJH&DWHJRU\

䊡䚸

3ROOXWLRQ'HJUHH

8VH6(/93RZHU6RXUFHIRUWKH'&PDLQSRZHUVRXUFH

5HSODFHDEOH%DWWHU\&-:%$7

Compliance with 

(

16WDQGDUG

Summary of Contents for NSH5 Series

Page 1: ...ng the PT check carefully for any external scratches or other damage Also shake the Units gently and check for any abnormal sound Install or hand hold the NSH5 when operating it Do not operate the NSH5 on the floor or on a tabletop Do not let metal particles enter the PT when preparing the panel Use power supplies with reinforced or double insulation and minimal voltage fluctuation for the NSH5 PT...

Page 2: ...Locations subject to strong ultraviolet light Locations subject to dust Locations subject to direct sunlight Take appropriate and sufficient countermeasures when installing sys tems in the following locations Locations subject to static electricity or other forms of noise Locations subject to strong electromagnetic or magnetic fields Locations close to power supply lines Locations subject to possi...

Page 3: ...me loose 8 Connect all of the connectors 1 2 3 4 ON Serial interface White 20 pin connector 24 VDC power supply interface Black 3 pin connector External output interface Black 18 pin connector Serial interface External output interface 24 VDC interface 9 When using RS 422A communications turn ON DIP switch pin 1 terminating resistance ON only when the PT is connected as the last communications nod...

Page 4: ...m the Special Cable Always connect the enabling switch to a safety circuit ENB1A1 ENB2A1 ENB2A2 ENB1A2 ENB1 ENB2 NSH5 Enabling switch DPST NO Special Cable Safety circuit z Function Switches The status of function switches F1 F2 F6 and F7 are output exter nally by direct outputs via the Special Cable F1 PLC F2 SW COM F1 NSH5 Function switches Four NO contacts output to external devices PLC PLC F6 ...

Reviews: