background image

Control panel

Relay cable (included)

Cut a cable clamp mounting hole in 
the control panel, using the cable 
diameter as a guide, then feed the 
cable through the hole.

*Connect the relay cable after first feeding
the UL-standard cable through the control panel wall.

Insert the cable clamp housing into the  
mounting hole in the control panel and  
secure it in place with the lock nut from the inside.  
Tighten the lock nut to a torque of 4.0 to 5.0 N·m.

Adjust the cable length,  
place the rubber cable packing  
inside the housing, and then tighten  
the cap to secure the cable.

„

„

Installing the 

Mounting Bracket

1.

As shown below, there are two holes for installing the mounting
bracket.

Mounting bracket holes 

2.

Secure the mounting bracket to the PT with the two screws.

Mounting bracket 

Note:

 Tighten the screws to a force of 0.9 N

m. 

3.

Attach a screw or other support to the wall first and then hook
the mounting bracket on it to install the NSH5.

Mounting bracket

Screw or other support 
(Provided by the customer)

Diameter: 5 mm

Diameter: 10 mm

„

External Wiring Diagram

z

 

External Output Interface 

Item 

Specification 

Function switches 

SPST-NO 
Rated voltage: 24 V 
Max. rated current: 50 mA 

Emergency stop 
switch/Stop switch 

3PST-NC 
Rated voltage: 24 V 
Max. rated current: 100 mA 
Min. applicable load: 1 mA at 5 VDC 

Enabling switch 

DPST-NO 
Rated voltage: 24 V 
Max. rated current: 100 mA 
Min. applicable load: 4 mA at 24 VDC 

z

 

Emergency Stop Switch 

The status of the emergency stop switch (DPST-NC contacts) is 
output externally by a direct output via the Special Cable. 

*

: Always connect the emergency stop switch to a safety circuit. 

EMG1A1

EMG2A1

EMG2A2

Safety circuit

 

EMG1A2

EMG1 EMG2 

NSH5 

Emergency stop switch
DPST-NC

Special Cable

z

 

Enabling Switch 

The status of the enabling switch (DPST-NO contact) is output ex-
ternally by a hard-wired output from the Special Cable. 

*

: Always connect the enabling switch to a safety circuit. 

ENB1A1

ENB2A1

ENB2A2

ENB1A2

ENB1 ENB2 

NSH5 

Enabling switch
DPST-NO

Special Cable

Safety  
circuit

z

 

Function Switches 

The status of function switches F1, F2, F6, and F7 are output exter-
nally by direct outputs via the Special Cable. 

F1  

PLC 

F2  

SW COM

F1

NSH5 

Function switches
Four NO contacts output to external devices

PLC 

PLC 

F6

PLC 

F7

F6  

F7  

F2

Special Cable

„

Reference Manuals

Name

Man No.

NSH5–series Operation Manual 

V090 

NS–series Programming Manual 

V073 

CX–Designer User’s Manual 

V099 

SUITABILITY FOR USE 

OMRON shall not be responsible for conformity with any standards, 
codes, or regulations that apply to the combination of products in the 
customer’s application or use of the products. 

Take all necessary steps to determine the suitability of the product for the sys-
tems, machines, and equipment with which it will be used. 
Please know and observe all prohibitions of use applicable to the products. 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS 
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM 
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT 
THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR 
THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 
See also product catalogs for Warranty and Limitations of Liability. 
Local support office: 

OMRON Corporation 
Industrial Automation Company 
Tokyo, JAPAN 

Contact: www.ia.omron.com 

Regional Headquarter 
OMRON EUROPE B.V. 

Wegalaan 67-69-2132 JD Hoofddorp 
The Netherlands 
Tel: (31)2356-81-300 
Fax: (31)2356-81-388 

OMRON ASIA PACIFIC PTE. LTD. 

No. 438A Alexandra Road # 05-05/08 
(Lobby 2), Alexandra Technopark,   
Singapore 119967 
Tel: (65) 6835-3011 
Fax: (65) 6835-2711

 

OMRON ELECTRONICS LLC 

*UHHQVSRLQW3DUNZD\6XLWH
+RIIPDQ(VWDWHV,/86$

 

Tel: (1) 847-843-7900 
Fax: (1) 847-843-7787 

OMRON (CHINA) CO., LTD. 

Room 2211, Bank of China Tower, 
200 Yin Cheng Zhong Road, 
PuDong New Area, Shanghai,   
200120, China 
Tel: (86) 21-5037-2222 
Fax: (86) 21-5037-2200

 

Note: 

Specifications subject to change without notice. 

Summary of Contents for NSH5 Series

Page 1: ...ng the PT check carefully for any external scratches or other damage Also shake the Units gently and check for any abnormal sound Install or hand hold the NSH5 when operating it Do not operate the NSH5 on the floor or on a tabletop Do not let metal particles enter the PT when preparing the panel Use power supplies with reinforced or double insulation and minimal voltage fluctuation for the NSH5 PT...

Page 2: ...Locations subject to strong ultraviolet light Locations subject to dust Locations subject to direct sunlight Take appropriate and sufficient countermeasures when installing sys tems in the following locations Locations subject to static electricity or other forms of noise Locations subject to strong electromagnetic or magnetic fields Locations close to power supply lines Locations subject to possi...

Page 3: ...me loose 8 Connect all of the connectors 1 2 3 4 ON Serial interface White 20 pin connector 24 VDC power supply interface Black 3 pin connector External output interface Black 18 pin connector Serial interface External output interface 24 VDC interface 9 When using RS 422A communications turn ON DIP switch pin 1 terminating resistance ON only when the PT is connected as the last communications nod...

Page 4: ...m the Special Cable Always connect the enabling switch to a safety circuit ENB1A1 ENB2A1 ENB2A2 ENB1A2 ENB1 ENB2 NSH5 Enabling switch DPST NO Special Cable Safety circuit z Function Switches The status of function switches F1 F2 F6 and F7 are output exter nally by direct outputs via the Special Cable F1 PLC F2 SW COM F1 NSH5 Function switches Four NO contacts output to external devices PLC PLC F6 ...

Reviews: