![background image](http://html.mh-extra.com/html/omron/nj-series/nj-series_network-connection-manual_742185081.webp)
10. Appendix 2 Setting the Tag Data Links Using the Software
78
9
Select
192.168.250.1
in the
Unregister Device List
Field.
Click the
Down Arrow
that is
shown in the dialog box.
10
192.168.250.1 is registered in
the Register Device List.
Select 192.168.250.1 and click
the
New
Button.
11
The Edit Connection Dialog Box
is displayed. Select the following
values from the pull-down lists
for the settings in the
Originator
Device
Field and the
Target
Device
Field.
■
Settings of connection
Connection allocation
Setting value
Input Tag Set
D10100 - [20Byte]
Originator device
Connection Type
Multi-cast connection
Target Device
Output Tag Set
EIP002_OUT - [20Byte]
12
Confirm that the settings are
correct and click the
Regist
Button.