1 5
OMRON Scientific Technologies Inc.
© OMRON STI 0613 PN99804-0060 Rev. B
52
15 D
IAGNOSTICS
& T
ROUBLESHOOTING
15
1 5 . 1 D
I AG NO S T IC S
The diagnostic fault codes are given in the following table. These codes are displayed via the IBIs.
Table 15-1 Diagnostic Codes
Code Group
Error Code
Description of Error Code
Corrective Action Needed
Configuration
Switch Faults
(MS4800S only)
21
Invalid mode selection setting
Verify switch setting. See user manual.
22
Configuration switch settings
changed during operation
Verify switch setting. See user manual.
23
Configuration switch settings
do not match
Verify switch setting. See user manual.
24
Corrupted EEPROM
configuration.
Reset the system configuration to
factory default.
26
Invalid scan code setting
Verify switch setting. See user manual.
Safety Output
(OSSD) Faults
31
Safety outputs 1 & 2 are
shorted together
Check and correct wiring of safety
outputs 1 and 2.
32
Safety output 1 shorted to
power
Check and correct wiring of safety
output 1.
33
Safety output 2 shorted to
power
Check and correct wiring of safety
output 2.
34
Safety output 1 shorted to
ground
Check and correct wiring of safety
output 1.
35
Safety output 2 shorted to
ground
Check and correct wiring of safety
output 2.
EDM Faults
41
EDM circuit did not open before
transition to MACHINE RUN
State
Check and correct EDM wiring.
42
EDM circuit did not open after
transition to MACHINE RUN
state
Check and correct EDM wiring.
43
EDM circuit was in wrong state
during power-up
Check and correct EDM wiring.
44
EDM fault at power-up
Check start input wire or EDM function
selection.
Controller Fault
50
Control logic fault
Call Omron STI(888-510-4357) or return
receiver to Omron STI for evaluation
Setup Error
60
Possible crosstalk
Possible crosstalk
Muting Faults
70
General muting fault
Check wiring of unused mute sensors.
71
Mute sensors activated in the
wrong sequence
Check mounting of mute sensors for
correct sequence.
74
Mute lamp burned out or not
connected
Check status of mute lamp.
Cascaded System
Faults
80
Configuration error
Call Omron STI for troubleshooting
assistance (888-510-4357)
81
Second segment or mute
module error
Check all cable connections. Call
Omron STI (888-510-4357)
82
Third segment or mute module
error
Check all cable connections. Call
Omron STI (888-510-4357)
83
Fourth segment or mute
module error
Check all cable connections. Call
Omron STI (888-510-4357)
84
Mute module error
Check all cable connections to mute
module. Call Omron STI (888-510-
4357)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]