OMRON Scientific Technologies Inc.
39
© OMRON STI 0613 PN99804-0060 Rev. B
13 S
PECIFICATIONS
AND
A
DDITIONAL
I
NFORMATION
13
1 3 . 1 S
Y S T E M
S
P E CI F IC AT IO NS
Table 13-1 System Specifications
Performance:
Protective Height
240-1800mm (14/20mm res.), 280-2120mm (30mm Res.), 360-
2040mm (40mm Res.)
Object Resolution
14, 20, 30, and 40mm
Operating Range
14mm resolution - 0.3 to 7m (1 to 23 ft.) default; 0.3 to 3m (1 to 10 ft.)
20, 30 and 40mm resolution - 0.3 to 20m (1 to 65 ft.) default; 0.3 to 8m
(1 to 26 ft.)
Effective Aperture Angle
± 2.5° maximum, transmitter and receiver at operating range greater
than 3 meters per IEC 61496-2.
Safety Output
Two PNP, each output sourcing 625 mA @ 24 VDC, short circuit
protected. (See note 2)
Response Time
See
Table 13-2
Light Source
Infrared Light Emitting Diode, 880 nm
Transmitter Indicator Lights
Active (Yellow)
Receiver Indicator Light
MACHINE RUN/Stop (green/red), INTERLOCK/Alarm (Yellow),
Blanking (amber)
Electrical:
Power Input Transmitter:
24 VDC ± 20% 285 mA max.
Power Input Receiver:
24 VDC ± 20% 1.7A max. (receiver 450mA + OSSD1 625 mA max. +
OSSD2 625 mA max. ). (See note 1)
Power Supply
Must meet requirements of IEC 60204-1 and IEC 61496. Omron STI
part number 42992 or equivalent. (See note 1 ).
Mechanical:
Construction
Polyurethane powder painted aluminum
Cable length
Available in 10, 15, and 30 m lengths, unshielded. (See note 3).
Wiring Connections
M12 connectors: 5-pin receiver and 5-pin transmitter.
Environmental:
Enclosure rating
IP65
Operating Temperature
-10 to 55° C (14 to 131 F)
Storage Temperature
-25 to 75° C (-14 to 167 F)
Relative Humidity
95% maximum, non-condensing
Vibration
10 - 55Hz maximum on all 3 axes
Shock
10g for 0.016 seconds; 1,000 shocks for each of three axes
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]