© OMRON STI 0613 PN99804-0060 Rev. B
where:
S = the minimum distance in millimeters, from the danger zone to the detection point, line, plane or
zone.
K = 1600 mm/s
T = the overall system stopping performance in seconds.
T = t
1
+ t
2
t
1
= response time of the safety light curtain in seconds. This response time is given in
Table 13-1
.
t
2
= maximum stopping time of the machine in seconds.
C = 850 mm.
i.e.:
S = (1600 mm/s x T) + 850 mm
8.2.3
F
ACTORS
A
FFE CTING
THE
S
AFETY
D
ISTANCE
F
ORMULA
When light curtains are used for machine initiation, their minimum object resolution must be 30 mm or
smaller (based on EN 999, other standards may vary). In this case the formula given in section
8.2.1
applies except that the minimum distance S shall be greater than 150 mm.
For parallel approach the formula for C becomes:
C = 1200 mm – (0.4 x H), but not less than 850 mm
H = the height of the detection zone above the floor in mm.