KP100G
40
Data Logger
KP100G can be easily communicated with the Data Logger.
Table 8-1 Specification of Data Logger
Displayed information
each input power, output power, operation mode and warning message
Data capacity
3 years
Storage media
Internal memory (SD card)
User can not exchange storage media.
Data download
Via USB (Type A to mini-B USB Cable)
Data download
User can download and manage the stored data by another computer. For KP100G, user can take out the data logger and access its internal data via
USB without providing external power. The power in this case is provided by USB port of computer.
Use can not download via communication such as RS-232C and RS-485.
For more information, please contact the store from which you purchased the product.
RS-232C Communications
The simplest and least expensive way to communicate between a single KP100G and a personal computer is to connect directly via RS-232C ports. The
maximum cable length between the personal computer and the KP100G is 15 m.
Fig, 8-3 Example of RS-232C communications with a single KP100G
RS-232C communications require the appropriate cable and a personal computer installed with monitoring software.
The RS-232C connection is shown in P.27.
Note: If the RS-485 card is inserted, RS-232C is not available. To use the RS-232C, remove the RS-485 card.
RS-232C