Process Indicator
K3HB-X
A Process Indicator Ideal for Discriminating and
Displaying Measurements for Voltage/Current
Signals
• Easy recognition of judgement results using color display that can be
switched between red and green.
*
• Equipped with a position meter for monitoring operating status trends.
• External event input allows use in various measurement and discrimina-
tion applications.
• Series expanded to include DeviceNet models.
• Short body with depth of only 95 mm (from behind the front panel), or 97
mm for DeviceNet models.
• UL certification approval (Certification Mark License).
• CE Marking conformance by third party assessment body.
• Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
• Capable of high-speed sampling at 50 times per second (20 ms)
• Easy-to-set two-point scaling allows conversion and display of any user-
set values.
*
Visual confirmation of judgement results is not supported on models that do not have
an output or models that do not support DeviceNet.
You can change the display color by setting it, but you cannot switch it based on the
judgement results.
Model Number Structure
■
Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
1. Input Sensor Code
VD: DC voltage input
AD: DC current input
VA: AC voltage input
AA: AC current input
5. Supply Voltage
100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
Base Units with Optional Boards
2. Sensor Power Supply/Output Type Code
None: None
CPA: Relay output (PASS: SPDT) + Sensor power supply
(12 VDC +/
−
10%, 80 mA) (See note 1.)
L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply
(12 VDC +/
−
10%, 80 mA) (See note 2.)
L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply
(12 VDC +/
−
10%, 80 mA) (See note 2.)
A: Sensor power supply (12 VDC +/
−
10%, 80 mA)
FLK1A: Communications (RS-232C) + Sensor power supply
(12 VDC +/
−
10%, 80 mA) (See note 2.)
FLK3A: Communications (RS-485) + Sensor power supply
(12 VDC +/
−
10%, 80 mA) (See note 2.)
Note: 1.
CPA can be combined with relay outputs only.
2.
Only one of the following can be used by each Digital Indicator:
RS-232C/RS-485 communications, a linear output, or
DeviceNet communications.
Optional Board
Sensor Power Supply/Output Boards
Relay/Transistor Output Boards
Event Input Boards
3. Relay/Transistor Output Type Code
None: None
C1: Relay contact (H/L: SPDT each)
C2: Relay contact (HH/H/LL/L: SPST-NO each)
T1: Transistor (NPN open collector: HH/H/PASS/L/LL)
T2: Transistor (PNP open collector: HH/H/PASS/L/LL)
BCD
*
: BCD transistor output (NPN open collector: HH/H/PASS/L/
LL)
DRT: DeviceNet (See note 2.)
*
A Special BCD Output Cable (sold separately) is required.
4. Event input Type Code
None: None
1: 5 inputs (M3 terminal blocks), NPN open collector
2
*
: 8 inputs (10-pin MIL connector), NPN open collector
3: 5 inputs (M3 terminal blocks), PNP open collector
4
*
: 8 inputs (10-pin MIL connector), PNP open collector
*
There is no bank selection for "None" and "DeviceNet" types of "Transistor
Output Type Code".
Note:
The following combinations are not possible.
• Communications (FLK
@
A) + DeviceNet (DRT)
• Communications (FLK
@
A) + BCD output (BCD)
• Linear current/voltage (L
@
A) + DeviceNet (DRT)
Refer to
Safety Precautions for All Digital Panel
Meters
.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
1
K3HB-X
@
5
1
2 3 4
K3HB-X
@
-
@@@
5
2
K33-
@
3
K34-
@
4
K35-
@