Common Specifications

Event Input Ratings

Output Ratings

Contact Output

Transistor Output

Linear Output

Serial Communications Output

Note:

For details on serial and DeviceNet communications, refer to
the 

Digital Indicator K3HB Communications User's Manual

(Cat.No. N129).

BCD Output I/O Ratings 
(Input Signal Logic: Negative)

Note:

For details on serial and DeviceNet communications, refer to
the 

Digital Indicator K3HB Communications User's Manual

(Cat.No. N129).

Input type

S-TMR, HOLD, RESET, ZERO, BANK1, BANK2, 

BANK4

TIMING

Contact

ON: 1 k

Ω 

max., OFF: 100 k

Ω 

min.

---

No-contact

ON residual voltage: 2 V max.
OFF leakage current: 0.1 mA max.
Load current: 4 mA max.
Maximum applied voltage: 30 VDC max.

ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current: 17 mA max.
Maximum applied voltage: 30 VDC max.

Item

Resistive loads

(250 VAC, cos

φ

=1; 

30 VDC, L/R=0 ms)

Inductive loads

(250 VAC, closed 

circuit, cos

φ

=0.4; 

30 VDC, L/R=7 ms)

Rated load

5 A at 250 VAC
5 A at 30 VDC

1 A at 250 VAC
1 A at 30 VDC

Mechanical life 
expectancy

5,000,000 operations

Electrical life 
expectancy

100,000 operations

Maximum load voltage

24 VDC

Maximum load current

50 mA

Leakage current

100 

μ

A max.

Item

0 to 20 mA

4 to 20 mA

0 to 5 V

1 to 5 V

0 to 10 V

Allowable load impedance

500 

Ω 

max.

5 k

Ω 

min.

Resolution

Approx. 10,000

Output error

±0.5%FS

±0.5%FS (1 V or less: ±0.15 V; no output for 0 V or less.)

Item

RS-232C, RS-485

Communications method

Half duplex

Synchronization method

Start-stop synchronization

Baud rate

9,600, 19,200, or 38,400 bps

Transmission code

ASCII

Data length

7 bits or 8 bits

Stop bit length

2 bits or 1 bit

Error detection

Vertical parity and FCS

Parity check

Odd, even

I/O signal name

Item

Rating

Inputs

REQUEST
HOLD
MAX
MIN
RESET

Input signal

No-voltage 
contact input

Input current for 
no-voltage input

10 mA

Signal 
level

ON voltage

1.5 V max.

OFF voltage 3 V min.

Outputs

DATA
POLARITY
OVER
DATA VALID
RUN

Maximum load 
voltage

24 VDC

Maximum load 
current

10 mA

Leakage current

100 

μ

A max.

HH
H
PASS
L
LL

Maximum load 
voltage

24 VDC

Maximum load 
current

50 mA

Leakage current

100 

μ

A max.

Summary of Contents for K3HB-X

Page 1: ...1 L1A Linear current output 0 to 20 or 4 to 20 mA DC Sensor power supply 12 VDC 10 80 mA See note 2 L2A Linear voltage output 0 to 5 1 to 5 or 0 to 10 VDC Sensor power supply 12 VDC 10 80 mA See note...

Page 2: ...tup compensa tion timer input NPN open collector or no voltage contact signal ON residual voltage 2 V max ON current at 0 4 mA max Max applied voltage 30 VDC max OFF leakage current 0 1 mA max Hold in...

Page 3: ...m s2 for relay outputs 3 times each in 3 axes 6 directions Weight Approx 300 g Base Unit only Degree of protection Front panel Conforms to NEMA 4X for indoor use equivalent to IP66 Rear case IP20 Term...

Page 4: ...nal CT current transformer 4 The K3HB XVA complies with UL standards when the applied input voltage is within the range 0 to 150 VAC If the input voltage is higher than 150 VAC install an external tra...

Page 5: ...at 250 VAC 5 A at 30 VDC 1 A at 250 VAC 1 A at 30 VDC Mechanical life expectancy 5 000 000 operations Electrical life expectancy 100 000 operations Maximum load voltage 24 VDC Maximum load current 50...

Page 6: ...ne Communications distance Baud rate Network length max Drop line length max Total drop line length max 500 Kbps 100 m 100 m 6 m 39 m 250 Kbps 100 m 250 m 6 m 78 m 125 Kbps 100 m 500 m 6 m 156 m The v...

Page 7: ...yed Used to switch level Used to switch the display between the PV maximum value and minimum value and to reset the maximum and minimum values PV display SV display Position meter SV display status in...

Page 8: ...ote Leave 20 ms min between DATA VALID turning OFF and the REQUEST signal See note See note See note Programmable Controller Connection Example Digital Indicator SYSMAC Programmable Controller DC Inpu...

Page 9: ...C 80 mA 12 VDC 80 mA 10 VDC 100 mA 10 VDC 100 mA Sensor power supply communications Sensor power supply Sensor power supply K33 CPB K33 CPA K33 B K33 A K33 L2B K33 L1B K33 L2A K33 L1A RS 485 K33 FLK3B...

Page 10: ...re also available E Analog Input D Event Input D6 3 9 k 4 7 k S TMR D2 HOLD D3 RESET D4 ZERO D5 12 V COM D6 D1 750 560 TIMING 12 V COM Models with Terminal Blocks K35 1 K35 3 Models with Connectors K3...

Page 11: ...atus Turns the comparative output OFF until the measurement value enters the PASS range Average processing of input signals with extreme changes or noise smooths out the display and makes control stab...

Page 12: ...r red to green The current display value can be selected from the present value the maximum value and the minimum value It is possible to specify i e restrict the values that the smallest dis played d...

Page 13: ...Higher Lower Output HH Output PASS Output H Output L Output LL Measurement value Higher Lower Measurement value Higher Lower Comparative set value HH Comparative set value H Comparative set value L C...

Page 14: ...cutout in the panel 2 Insert watertight packing around the Unit to make the mounting watertight 3 Insert the fixture into the grooves on the left and right sides of the rear case and push until it rea...

Page 15: ...turn OFF the power 19 Use the specified cables for the communications lines and stay within the specified DeviceNet communications distances Refer to the User s Manual Cat No N129 for details on comm...

Page 16: ...e running lines along separate ducts and using shield lines Example of Countermeasures for Inductive Noise on Input Lines 4 If a noise filter is used for the power supply check the voltage and current...

Page 17: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: