background image

K3HB-X

6

DeviceNet Communications

Internal Block Diagram

Communications protocol

Conforms to DeviceNet

Supported communi-
cations

Remote I/O communications

Master-Slave connection (polling, bit-strobe, COS, cyclic)
Conforms to DeviceNet communications standards. 

I/O allocations

Allocate any I/O data using the Configurator.
Allocate any data, such as DeviceNet-specific parameters and variable area for Digital 
Indicators.
Input area: 2 blocks, 60 words max.
Output area: 1 block, 29 words max.
(The first word in the area is always allocated for the Output Execution Enabled Flags.) 

Message communications

Explicit message communications
CompoWay/F communications commands can be executed (using explicit message 
communications) 

Connection methods

Combination of multi-drop and T-branch connections (for trunk and drop lines)

Baud rate

DeviceNet: 500, 250, or 125 Kbps (automatic follow-up)

Communications media

Special 5-wire cable (2 signal lines, 2 power supply lines, 1 shield line)

Communications distance

Baud rate

Network length 

(max.)

Drop line length 

(max.)

Total drop line 

length (max.)

500 Kbps

100 m (100 m)

6 m

39 m

250 Kbps

100 m
(250 m)

6 m

78 m

125 Kbps

100 m
(500 m)

6 m

156 m

The values in parentheses are for Thick Cable. 

Communications power supply

24-VDC DeviceNet power supply

Allowable voltage fluctuation range

11 to 25-VDC DeviceNet power supply

Current consumption

50 mA max. (24 VDC)

Maximum number of nodes

64 (DeviceNet Configurator is counted as one node when connected)

Maximum number of slaves

63

Error control checks

CRC errors

DeviceNet power supply

Supplied from DeviceNet communications connector

ADC

EEP-ROM

Analog inp

u

t

E

v

ent inp

u

t

De

v

ice

N

et

X

V

O

V

O

BCD I/O

Sensor po

w

er

s

u

pply

Keys

Micro-

comp

u

ter

W

a

v

eform

shaping circ

u

it

Dri

v

e

circ

u

it

Indications

Dri

v

e

circ

u

it

Digital inp

u

circ

u

it

Filter

Inp

u

circ

u

it

BCD

 Inp

u

t circ

u

it

 O

u

tp

u

t circ

u

it

 Transistor 

  

 

o

u

tp

u

t circ

u

it

Dri

v

e

circ

u

it

Dri

v

e

circ

u

it

Dri

v

e

circ

u

it

Dri

v

e

circ

u

it

Transistor
o

u

tp

u

t

Relay o

u

tp

u

t

Linear o

u

tp

u

t

Comm

u

nications

De

v

ice

N

et

circ

u

it

Comm

u

ni-

cations

dri

v

er

Po

w

er s

u

pply

Po

w

er s

u

pply circ

u

it (isolated)

V

DD

V

COM

DC-DC

Con

v

erter (isolated)

Linear o

u

tp

u

t

circ

u

it

Summary of Contents for K3HB-X

Page 1: ...1 L1A Linear current output 0 to 20 or 4 to 20 mA DC Sensor power supply 12 VDC 10 80 mA See note 2 L2A Linear voltage output 0 to 5 1 to 5 or 0 to 10 VDC Sensor power supply 12 VDC 10 80 mA See note...

Page 2: ...tup compensa tion timer input NPN open collector or no voltage contact signal ON residual voltage 2 V max ON current at 0 4 mA max Max applied voltage 30 VDC max OFF leakage current 0 1 mA max Hold in...

Page 3: ...m s2 for relay outputs 3 times each in 3 axes 6 directions Weight Approx 300 g Base Unit only Degree of protection Front panel Conforms to NEMA 4X for indoor use equivalent to IP66 Rear case IP20 Term...

Page 4: ...nal CT current transformer 4 The K3HB XVA complies with UL standards when the applied input voltage is within the range 0 to 150 VAC If the input voltage is higher than 150 VAC install an external tra...

Page 5: ...at 250 VAC 5 A at 30 VDC 1 A at 250 VAC 1 A at 30 VDC Mechanical life expectancy 5 000 000 operations Electrical life expectancy 100 000 operations Maximum load voltage 24 VDC Maximum load current 50...

Page 6: ...ne Communications distance Baud rate Network length max Drop line length max Total drop line length max 500 Kbps 100 m 100 m 6 m 39 m 250 Kbps 100 m 250 m 6 m 78 m 125 Kbps 100 m 500 m 6 m 156 m The v...

Page 7: ...yed Used to switch level Used to switch the display between the PV maximum value and minimum value and to reset the maximum and minimum values PV display SV display Position meter SV display status in...

Page 8: ...ote Leave 20 ms min between DATA VALID turning OFF and the REQUEST signal See note See note See note Programmable Controller Connection Example Digital Indicator SYSMAC Programmable Controller DC Inpu...

Page 9: ...C 80 mA 12 VDC 80 mA 10 VDC 100 mA 10 VDC 100 mA Sensor power supply communications Sensor power supply Sensor power supply K33 CPB K33 CPA K33 B K33 A K33 L2B K33 L1B K33 L2A K33 L1A RS 485 K33 FLK3B...

Page 10: ...re also available E Analog Input D Event Input D6 3 9 k 4 7 k S TMR D2 HOLD D3 RESET D4 ZERO D5 12 V COM D6 D1 750 560 TIMING 12 V COM Models with Terminal Blocks K35 1 K35 3 Models with Connectors K3...

Page 11: ...atus Turns the comparative output OFF until the measurement value enters the PASS range Average processing of input signals with extreme changes or noise smooths out the display and makes control stab...

Page 12: ...r red to green The current display value can be selected from the present value the maximum value and the minimum value It is possible to specify i e restrict the values that the smallest dis played d...

Page 13: ...Higher Lower Output HH Output PASS Output H Output L Output LL Measurement value Higher Lower Measurement value Higher Lower Comparative set value HH Comparative set value H Comparative set value L C...

Page 14: ...cutout in the panel 2 Insert watertight packing around the Unit to make the mounting watertight 3 Insert the fixture into the grooves on the left and right sides of the rear case and push until it rea...

Page 15: ...turn OFF the power 19 Use the specified cables for the communications lines and stay within the specified DeviceNet communications distances Refer to the User s Manual Cat No N129 for details on comm...

Page 16: ...e running lines along separate ducts and using shield lines Example of Countermeasures for Inductive Noise on Input Lines 4 If a noise filter is used for the power supply check the voltage and current...

Page 17: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: