G-126

Safety Sensors / Components

G9SB-200-D (24 VAC/VDC) or G9SB-301-D (24 VAC/VDC) with 2-channel Safety Area Sensor/Manual-reset

Note: This circuit conforms to EN954-1 Safety Category 4.

KM1 KM2

S1

KM1

KM2

E1

KM1

KM2

M

K1

K2

K1

K1

K2

K2

K1

a

a

+

-

K2

TH

SA

A1 A2

T11

T12

T31

T32

13

41

33

14

24

34

42

T21

T22

23

*

*

*

*

Emitter

Receiver

Open

Open

Open

Open

Feedback loop

Control 
circuit

Timing Chart

F3SN-A: Incident 

Interrupted

Reset switch S1

K1 and K2 (NC)

K1 and K2 (NO)

KM1 and KM2 (NC)

KM1 and KM2 (NO)

Note: 

Output turns ON with the rising edge of re-
set switch S1, but will not operate if there is 
a short breakdown in S1.

F3SN-A:

Safety Area Sensor

S1:

Reset switch

KM1 and KM2: Magnetic Contactor
M:

3-phase motor

E1:

24-VDC power supply

Note: 

Only the G9SB-301-D 

model has terminals 
33-34 and 41-42.

See note.

Shield

0V (Blue)

OSSD2 (White)

OSSD1 (Green)

Auxiliary (Yellow)

EDM input (Red)

+24 V (Brown)

F3SN-A
F3SH-A

+24 V (Brown)

Interlock selection 

input (White)

Reset input (Yellow)

Test input (Green)

(Red)

0V (Blue)

Shield

RS-485(A) (Gray)

RS-485(B) (Pink)

F502-EN2-04.book  Seite 126  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for G9SB

Page 1: ...hannel or 2 channel input possible 0 None direct breaking 2 2 channel input 6 Miscellaneous A Auto reset inverse input B Auto reset common input C Manual reset inverse input D Manual reset common inpu...

Page 2: ...9SB 3010 G9SB 301 Resistive load cos 1 Rated load 250 VAC 5 A Rated carry current 5 A Item G9SB 200 G9SB 3010 G9SB 301 Contact resistance See note 1 100 m Operating time See note 2 30 ms max Response...

Page 3: ...T22 Feedback loop Control circuit Timing Chart Limit switches S1 and S2 K1 and K2 NC K1 and K2 NO KM1 and KM2 NC KM1 and KM2 NO S1 Safety limit switch with direct opening mechanism D4N or D4B S2 Limit...

Page 4: ...rrupted Reset switch S1 K1 and K2 NC K1 and K2 NO KM1 and KM2 NC KM1 and KM2 NO Note Output turns ON with the rising edge of re set switch S1 but will not operate if there is a short breakdown in S1 F...

Page 5: ...1 12 23 24 S2 S1 KM1 KM2 K1 K2 K1 K1 K2 K2 K1 a a K2 TH SA A1 A2 T31 T32 13 23 33 41 14 24 34 42 Open Feedback loop Control circuit Timing Chart Limit switches S1 and S2 K1 and K2 NC K1 and K2 NO KM1...

Page 6: ...24 34 PWR K1 K2 PWR K1 K2 83 18 2 5 68 48 2 6 2 5 10 112 max 100 max 18 max Average 17 5 Terminal Arrangement G9SB 200 G9SB 3010 green green orange orange orange orange 83 18 2 5 68 48 2 6 13 23 33 T1...

Page 7: ...2 It is not possible to wire G9SB 2 A C models for 1 channel input 2 Only G9SB 301 models have terminals 33 34 and 41 42 K1 K2 K1 K1 K2 K2 K1 a a K2 TH SA A1 A2 T11 T12 T31 T32 13 23 33 41 14 24 34 42...

Page 8: ...ry is deter mined from the whole safety control system Make sure that the whole safety control system meets EN954 1 requirements Mounting Multiple Units When mounting multiple Units close to each othe...

Reviews: