background image

G9S

B

G-129

G9SB

Installation

Internal connections

G9SB-2002-A/C (24 VAC/VDC)
G9SB-3012-A/C (24 VAC/VDC)

G9SB-200-B/D (24 VAC/VDC)
G9SB-301-B/D (24 VAC/VDC)

G9SB-3010 (24 VDC)

Note: 1. For 1-channel input with G9SB-

###

-B/D models, short terminals T12 and T22. 

It is not possible to wire G9SB-

###

2-A/C models for 1-channel input.

2. Only G9SB-301

#

-

#

 models have terminals 33-34 and 41-42.

K1

K2

K1

K1

K2

K2

K1

a

a

+

-

K2

TH

SA

A1 A2 T11

T12

T31

T32

13

23

33

41

14

24

34

42

T21

T22

* *

* *

Control 
circuit

See note 2.

K1

K2

K1

K1

K2

K2

K1

a

a

+

-

K2

TH

SA

A1 A2

T11

T12

T31

T32

13

41

33

14

24

34

42

T21

T22

23

* *

* *

Control 
circuit

See note 2.

K1

K2

K1

K1

K2

K2

K1

a

a

+

-

K2

TH

SA

A1

A2

T31

T32

13

23

33

41

14

24

34

42

Control 
circuit

F502-EN2-04.book  Seite 129  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for G9SB

Page 1: ...hannel or 2 channel input possible 0 None direct breaking 2 2 channel input 6 Miscellaneous A Auto reset inverse input B Auto reset common input C Manual reset inverse input D Manual reset common inpu...

Page 2: ...9SB 3010 G9SB 301 Resistive load cos 1 Rated load 250 VAC 5 A Rated carry current 5 A Item G9SB 200 G9SB 3010 G9SB 301 Contact resistance See note 1 100 m Operating time See note 2 30 ms max Response...

Page 3: ...T22 Feedback loop Control circuit Timing Chart Limit switches S1 and S2 K1 and K2 NC K1 and K2 NO KM1 and KM2 NC KM1 and KM2 NO S1 Safety limit switch with direct opening mechanism D4N or D4B S2 Limit...

Page 4: ...rrupted Reset switch S1 K1 and K2 NC K1 and K2 NO KM1 and KM2 NC KM1 and KM2 NO Note Output turns ON with the rising edge of re set switch S1 but will not operate if there is a short breakdown in S1 F...

Page 5: ...1 12 23 24 S2 S1 KM1 KM2 K1 K2 K1 K1 K2 K2 K1 a a K2 TH SA A1 A2 T31 T32 13 23 33 41 14 24 34 42 Open Feedback loop Control circuit Timing Chart Limit switches S1 and S2 K1 and K2 NC K1 and K2 NO KM1...

Page 6: ...24 34 PWR K1 K2 PWR K1 K2 83 18 2 5 68 48 2 6 2 5 10 112 max 100 max 18 max Average 17 5 Terminal Arrangement G9SB 200 G9SB 3010 green green orange orange orange orange 83 18 2 5 68 48 2 6 13 23 33 T1...

Page 7: ...2 It is not possible to wire G9SB 2 A C models for 1 channel input 2 Only G9SB 301 models have terminals 33 34 and 41 42 K1 K2 K1 K1 K2 K2 K1 a a K2 TH SA A1 A2 T11 T12 T31 T32 13 23 33 41 14 24 34 42...

Page 8: ...ry is deter mined from the whole safety control system Make sure that the whole safety control system meets EN954 1 requirements Mounting Multiple Units When mounting multiple Units close to each othe...