System Configuration
10
FQ Short Manual
2-1 System Configuration
Do not connect network devices other than PLCs on the same network as the Touch Finder or computer. If
another device is connected, the responsiveness of displays and settings of the Touch Finder or computer may
become slow.
Product
Model number
Remarks
FQ Vision Sensor
FQ-S
@@@@@@
This is the Vision Sensor.
Touch Finder
FQ-D
@@
This is a setup console.
PC Tool
---
The PC Tool can be used instead of the Touch
Finder. If you register as a member, you can down-
load the free PC Tool as a special service to pur-
chasers.
Refer to the
Member Registration Sheet
that is
enclosed with the Sensor for the member registra-
tion procedure and the download procedure for spe-
cial member software.
FQ Ethernet Cable
FQ-WN0
@@
Connects the Sensor to the Touch Finder or com-
puter.
Standard RJ45 Ethernet
Cable
---
Connects the switching hub to the Touch Finder or
computer. (STP (shielded twisted-pair) cable, cate-
gory 5e or 6, impedance: 100
Ω
)
I/O Cable
FQ-WD0
@@
Connects the Sensor to the power supply and exter-
nal devices.
Switching Hub
W4S1-0
@@
Used to connect multiple Sensors to one Touch
Finder or PC Tool.
PLC
Switching Hub
Standard RJ45 Ethernet
Cable
FQ Ethernet Cable
Connect the trigger
sensor, PLC, and
power supply to
each Sensor.
Touch Finder or PC Tool
Setup Tool
FQ Vision Sensors
(8 max.)
24-VDC power supply
24-VDC power
supply
FQ Ethernet Cable
I/O Cable
Touch Finder or PC Tool
Setup Tool
FQ Vision Sensor
Standard Configuration
Multiple Connection Sensors
Trigger Sensor
Important