Setting the Outputs
FQ Short Manual
65
7
Co
mm
un
ic
a
tio
n
s
wi
th
Exte
rn
al
De
vi
ce
s
7-3 Setting the Outputs
Using the Overall Judgement Result
When the results of the inspection items are judged, if even one individual judgement result is NG, the OR
output signal is turned ON.
Wiring
Timing Chart
The OR signal that is output is held until the next overall judgement is output.
*1: The timing for updating the OR signal is when the measurement results are finalized, regardless of the output settings of the BUSY signal
(BUSY output conditions).
Color
Signal
Description
The signals shown at the left are used.
Refer to the following information for signal wiring.
Black
OUT0 (OR)
Overall judgement (default
assignment)
2-3 Wiring: p. 15
OK
NG
OK
Inspection
item 31
If there is even one NG judgement,
the overall judgement will be NG
and the output will be turned ON.
NG (OR signal ON)
Inspection
item 1
Overall judgement
Inspection
item 0
Individual judgement results
OFF
ON
OFF
ON
Overall judgement *1
Turned ON when overall
judgement is NG.
(Output polarity: ON for NG)
OR signal
ON while measurements are
being processed (depends
on BUSY output conditions)
BUSY signal
TRIG signal
ON for 1 ms min.