Inspecting with the Edge Width Inspection Item
FQ Short Manual
4
Settin
g Up In
spections
41
Step 2
Teaching
Teaching means to store the region and the edge width in the region as reference data for the measurement.
[Inspect]
−
[Add item.]
−
[Edge Width]
−
[Settings] Tab Page
The following data is stored as the measurement reference.
Step 3
Adjusting the Judgement Parameters
[Inspect]
−
[Add item.]
−
[Edge Width]
−
[Settings] Tab Page
1
Press [Teach].
2
Place the object that is to be used as the measure-
ment reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
5
Press [TEACH] on the lower right of the display.
The basic settings will be registered when teaching has
been completed.
6
Press [Back] to end teaching.
Item
Parameter
Description
Reference data
Reference width
The reference edge width is set automatically.
1
Press [Judgement].
2
Set the D. Width range for an OK judgement.
Continuous measurements will be performed for the im-
ages that are displayed.
3
Press [OK] to enter the value.
Item
Parameter
Setting
Description
Judgement Parameter
D. Width
Range:
−
893 to 893
Default: Lower limit:
−
893, Upper
limit: 893
Set the upper and lower limits of the
reference width for an OK judgement.
The middle arrow is the direction for
detecting an edge.
Moves the
end point of
the
measure-
ment region.
Changes the
width of the
measure-
ment region.
Moves the
starting
point of the
measure-
ment
region.
Drag to
move the
region.
Blue for OK. Red for NG.
Upper limit
Lower limit