E3X-DA-S
3
Ratings and Specifications
Fiber Amplifier Units
*1.
The E3X-DA0-S Amplifier Unit allows you to use an E3X-ECT EtherCAT Sensor Communications Unit or E3X-CRT CompoNet Sensor Communications Unit.
*2.
Only for Pre-wired models.
*3.
The following details apply to inputs.
*4.
The communications function and mutual interference prevention function are disabled if the detection mode is set to Super-high-speed mode.
*5.
Mutual interference prevention is enabled if Fiber Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-S-series
Units and E3C-LDA-series Units are used together. If power tuning is enabled, mutual interference prevention can be used for up to six units.
*6.
For the standard models E3X-DA
@
-S (
@
: 21/51/7/9/0), the rated sensing distance is approximately 1/2 and the incident level is approximately
1/3 of the normal levels when ECO mode is enabled.
Type
Standard models
Ultra-long-term APC
models
High-speed response
models
Standard models
Model for Sensor
Communications Unit
Item
Model
E3X-DA
@
-S
(
@:
21/51/7/9)
E3X-DA0-S*
1
E3X-DA
@
R-S
(
@:
21/51/7/9)
E3X-DA
@
F-S
(
@:
21/51/7/9)
Light source (wavelength)
Red,4-element LED (625 nm)
Power supply voltage
12 to 24 VDC
±
10%,
ripple (p-p) 10% max.
Supplied from the
connector through the
Sensor Communications
Unit
12 to 24 VDC
±
10%, ripple (p-p) 10% max.
Power consumption
Normal mode
: 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC)
Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC)
Control output /
APC alarm output
✽
1
Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 2 V max.
External input
✽
2
No-voltage input
(contact/transistor)
✽
3
---
No-voltage input
(contact/transistor)
✽
3
---
Protection circuits
Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection
Re-
sponse
time
Super-high-
speed Mode
✽
4
Operate or reset: 80
μ
s
---
Operate or reset: 80
μ
s
NPN output: Operate: 46
μ
s,
Reset: 48
μ
s
PNP output: Operate: 51
μ
s,
Reset: 53
μ
s
High-speed Mode
Operate or reset: 250
μ
s
---
Standard Mode
Operate or reset: 1 ms
High-resolution Mode
Operate or reset: 4 ms
Tough Mode
Operate or reset: 16 ms
Sensitivity setting
Teaching or manual method
Func-
tions
Power tuning
Light emission power and reception gain, digital control method
Differential
detection
Switchable between Single-edge and Double-edge Detection Modes.
Single edge: Set to 250
μ
s, 500
μ
s, 1 ms, 10 ms, or 100 ms.
Double edge: Set to 500
μ
s, 1 ms, 2 ms, 20 ms, or 200 ms
---
Automatic power
control (APC)
Always enabled.
High-speed control of emission current
Wide-range APC for the E3X-DA
@
R-S
Timer
Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1-s increments)
ATC
Provided
APC margin
display
---
Provided
---
Slow-motion
display
---
Provided
Zero reset
Negative values can be displayed. (Threshold value is shifted.)
Resetting settings
Select from initial reset (factory defaults) or user reset (saved settings).
Mutual
interference
prevention
Possible for up to 10 units
✽
5
---
ECO Mode
✽
6
Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital display OFF).
External input
setting
✽
2
Select from teaching operations, power tuning, zero reset, emitter OFF, or ATC start. ---
Output setting
Select from output for each channel, area output, or self-
diagnosis.
---
Indicator
Operation indicator for channel 1(orange)
Operation indicator for channel 2(orange)
Operation indicator for
channel 1(orange)
APC alarm output indicator (orange)
Operation indicator for
channel 1(orange)
Power tuning indicator (orange)
Contact input (relay or switch)
Non-contact input (transistor)
NPN
ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
PNP
ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)