background image

READ AND UNDERSTAND THIS DOCUMENT

Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.

WARRANTY

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE

THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED.  THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES.  Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.

At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,

safety equipment, and installations subject to separate industry or government regulations.

• Systems, machines, and equipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA

Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION

This document shall not be copied for sales or promotions without permission.

This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.

Summary of Contents for E3X-DA-S

Page 1: ...the E3X DRT21 S VER 3 use an E3X CN02 Connector without a Cable for the Wire saving Connector Sensor Communications Unit Connector Models for EtherCAT and CompoNet Dimensions page 29 For the most rec...

Page 2: ...connector 3 E3X CN11 Slave connector 1 E3X CN12 Appearance Model Quantity E39 L143 1 Appearance Model Quantity PFP M 1 Types Standard models 1 Ultra long term APC models High speed response models Co...

Page 3: ...igh speed Mode 4 Operate or reset 80 s Operate or reset 80 s NPN output Operate 46 s Reset 48 s PNP output Operate 51 s Reset 53 s High speed Mode Operate or reset 250 s Standard Mode Operate or reset...

Page 4: ...Vibration resistance Destruction 10 to 55 Hz with a 1 5 mm double amplitude for 2 hours each in X Y and Z directions 10 to 150 Hz with a 0 7 mm double amplitude for 80 min each in X Y and Z direction...

Page 5: ...D211R 2M 140 100 60 40 16 M6 E32 D11R 2M 840 600 350 240 100 E32 CC200 2M 1 400 1 000 600 400 180 E32 LD11 2M 860 610 360 250 110 E32 LD11R 2M 840 600 350 240 100 Sensing method Size Sensing directio...

Page 6: ...0 350 240 100 E32 D25 S3 2M 250 170 110 72 30 Type Spot diameter Center distance mm Model Sensing distance mm Tough mode High resolution mode Standard mode High speed mode Super high speed mode Variab...

Page 7: ...800 500 200 Top view 12 E32 T11 2M E39 F1 4 000 2 4 000 2 4 000 2 4 000 2 1 860 6 E32 T11 2M E39 F16 4 000 2 4 000 2 4 000 2 4 000 2 4 000 2 Side view 60 E32 T11 2M E39 F2 2 300 1 640 1 320 860 320 To...

Page 8: ...mode High speed mode Super high speed mode Limited reflective Small size Flat view E32 L24S 2M 0 to 4 Standard E32 L16 N 2M 0 to 15 0 to 12 Glass substrate alignment 70 C E32 A08 2M 10 to 20 Standard...

Page 9: ...tive 100 C E32 D51R 2M 670 480 280 190 80 150 C E32 D51 2M 1 120 800 450 320 144 200 C E32 D81R S 2M 420 300 180 120 54 300 C E32 A08H2 2M 10 to 20 E32 A09H2 2M 20 to 30 center 25 350 C E32 D611 S 2M...

Page 10: ...resolution mode Standard mode High speed mode Super high speed mode Limited reflective Glass presence detection 70 C E32 L16 N 2M 0 to 15 0 to 12 Glass substrate alignment E32 A08 2M 10 to 20 300 C E3...

Page 11: ...200 90 E32 LD11 2M 430 305 180 125 55 E32 LD11R 2M 420 300 170 120 50 Sensing method Size Sensing direction Model Sensing distance mm Tough mode High resolution mode Standard mode High speed mode Supe...

Page 12: ...pot diameter Center distance mm Model Sensing distance mm Tough mode High resolution mode Standard mode High speed mode Super high speed mode Variable spot 0 1 to 0 6 dia 6 to 15 E32 C42 1M E39 F3A Sp...

Page 13: ...660 430 160 Top view 12 E32 T51R 2M E39 F1 4 000 2 3 900 2 900 1 900 760 6 E32 T51R 2M E39 F16 4 000 2 4 000 2 4 000 2 3 600 1 400 Side view 60 E32 T51R 2M E39 F2 700 500 360 250 100 Top view 12 E32...

Page 14: ...Sensing distance mm Tough mode High resolution mode Standard mode High speed mode Super high speed mode Through beam Oil resistant Right angle E32 T11NF 2M 4 000 1 4 000 1 4 000 1 3 100 1 200 Chemica...

Page 15: ...840 560 220 E32 T16JR 2M 1 370 980 750 480 190 30 mm E32 T16WR 2M 2 000 1 700 1 300 850 340 Reflective Array 11 mm E32 D36P1 2M 350 250 150 100 45 Sensing method Tube diameter Feature Model Sensing di...

Page 16: ...38 300 C E32 A09H2 2M 20 to 30 center 25 Wet processes Cleaning Resist developing and etching 60 C E32 L11FP 2M 8 to 20 mm from tip of lens Recommended detection distance 11 mm 19 to 31 mm from center...

Page 17: ...OFF Operate Reset Between brown and black orange leads ch1 ch2 Operation indicator orange Output transistor Load e g relay Incident light No incident light ON OFF ON OFF Operate Reset Between brown an...

Page 18: ...t value Incident level Threshold Setting Thresholds Manually RUN Mode 3 Display Error Action A threshold can be set manually A threshold can also be adjusted manually after teaching to fine tune it Th...

Page 19: ...edure SET You can set the threshold to below the incident light level without a workpiece by the percentage set for the teaching level will be displayed With no workpiece With no workpiece The thresho...

Page 20: ...he UP and DOWN Keys to change the settings UP DOWN Light ON Dark ON 0 Operation mode Used to set the differential response time Single edge Double edge Differential edge differential operation selecte...

Page 21: ...l unit number Normal display Up down reversed display 7 Display orientation Used to reverse the orientation of the display Used to enable or disable the ECO mode Used to display the peak and bottom le...

Page 22: ...elector Switch to RUN Factory setting Press both for 3 s Press both for 3 s Press both for 3 s Press both for 5 s 3 s MODE MODE UP DOWN SET All settings can be returned to the factory defaults or to u...

Page 23: ...larm output indicator will light regardless of the operation of the APC margin display Set the SET RUN Mode Selector Switch to RUN Factory set to RUN Press the MODE Key to display the following for 10...

Page 24: ...nge of the incident level Error Display 2 Changes of the incident level for high speed workpiece detection can be displayed This enables checking the margin level of light received and the workpiece O...

Page 25: ...load or the load line before turning OFF the power supply to the sensor Mutual Interference Protection Function Mutual interference prevention is enabled if Amplifier Units are connected together It...

Page 26: ...M correctly due to a power failure or static electric noise initialize the settings with the keys on the Amplifier Unit ERR EEP will flash on the display when a writing error has occurred Optical Comm...

Page 27: ...Attached Mounting Holes 16 5 9 4 Mounting Bracket E39 L143 SUS304 stainless steel sold separately 16 18 7 4 3 4 3 18 7 4 3 Vinyl insulated round cable Standard length 2 m 2 Hole for optical communica...

Page 28: ...f DIN track DIN track sold separately PFP N Mounting Bracket E39 L143 SUS304 stainless steel sold separately Hole for optical communications 16 18 7 4 3 8 1 4 3 8 1 10 3 16 Wire saving Connector Model...

Page 29: ...4 11 7 11 75 12 15 3 25 29 8 Two 3 2 dia 18 7 Master Connector E3X CN21 7 2 000 50 0 Edge of amplifier E3X CN21 4 dia vinyl insulated round cable with 4 conductors Conductor cross section 0 2 mm2 Ins...

Page 30: ...000 50 0 Edge of amplifier Slave Connector E3X CN12 7 Cable 2 6 dia vinyl insulated round cable with 1 conductors Conductor cross section 0 2 mm2 Insulator diameter 1 1 mm 2 000 50 0 Edge of amplifie...

Page 31: ...y be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control system...

Page 32: ...5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 811 199 Contact ww...

Reviews: