![background image](http://html1.mh-extra.com/html/omron/e3x-da-s/e3x-da-s_manual_741171002.webp)
E3X-DA-S
2
Accessories (sold separately)
Wire-saving Connectors (Required for models for Wire-saving Connectors.)
Protection stickers attached
[Dimensions
➜
page 29]
Note:
The E3X-CN11/12 can also be used to connect to the E3X-DA
@
-S (
@
: 7/9) or the E3X-DA
@
R-S (
@
: 7/9), but the output lines will support
only 1 channel. Output function for channel 2 or APC alarm output function will be disabled.
Mounting Brackets
[Dimensions
➜
page 30]
End Plate
[Dimensions
➜
page 30]
Product Overview
}
: Strong point of the model
{
: Provided ---: Not provided
*
1.2. Except for the response time, the Sensor Communications Unit Connector Models for EtherCAT and CompoNet have the same I/O,
performance, and functions as the Standard, Wire-saving Connector Models.
(The fastest response time of the Sensor Communications Units Connector Models is 250
μ
s.)
Type
Appearance
Cable length
No. of conductors
Model
Master connector
2 m
4
E3X-CN21
Slave connector
2
E3X-CN22
Master connector
3
E3X-CN11
Slave connector
1
E3X-CN12
Appearance
Model
Quantity
E39-L143
1
Appearance
Model
Quantity
PFP-M
1
Types
Standard models
✽
1
Ultra-long-term APC models
High-speed response models
Connecting
method
Pre-wired
Wire-saving
connector
Pre-wired
Wire-saving
connector
Pre-wired
Wire-saving
connector
Item
Models
E3X-DA21-S
E3X-DA51-S
E3X-DA7-S
E3X-DA9-S
E3X-DA21R-S
E3X-DA51R-S
E3X-DA7R-S
E3X-DA9R-S
E3X-DA21F-S
E3X-DA51F-S
E3X-DA7F-S
E3X-DA9F-S
Input/output
External input
1 input
---
1 input
---
---
Output
2 outputs
1 output and 1 APC alarm output
1 output
Performance
Sensing distance
with E32-T11R
280 to 2,000 mm
(Depends on response time)
140 to 1,000 mm
(Depends on response time)
280 mm
(Only Super-high-speed Mode)
Sensing distance
with E32-D11R
100 to 840 mm
(Depends on response time)
50 to 420 mm
(Depends on response time)
100 mm
(Only Super-high-speed Mode)
Giga Power
(GIGA RAY)
}
(Margin:
×
160)
{
{
High-speed
response
✽
2
(fastest response
time)
{
(80
μ
s)
{
(80
μ
s)
}
(46
μ
s)
Function
Power tuning
{
{
{
Automatic power
control (APC)
{
}
(Ultra-long-term APC)
{
Timer
{
{
{
ATC
{
{
{
Key lock
{
{
{
Easy key lock
(switchable)
---
{
{
APC margin
display
---
{
---
Slow-motion display
---
---
{