![background image](http://html1.mh-extra.com/html/omron/e3x-da-s/e3x-da-s_manual_741171009.webp)
E3X-DA-S
9
E3X-DA
@
-S (
@
: 21/51/7/9/0)
E3X-DA
@
F-S(
@
: 21/51/7/9)
Bending-resistant
Heat-resistant
Area Beam
*
The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Liquid-level Detection
Note:
The High-speed Mode cannot be used with the E3X-DA0-S.
Sensing
method
Size
Model
Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-high-
speed mode
Through-
beam
1.5 dia.
E32-T22B 2M
680
480
400
220
90
M3
E32-T21 2M
M4
E32-T11 2M
2,500
1,800
1,350
900
360
Square E32-T25XB
2M
500
360
300
170
70
Reflective
1.5 dia.
E32-D22B 2M
140
100
60
40
16
M3
E32-D21 2M
3 dia.
E32-D221B 2M
300
220
140
90
40
M4
E32-D21B 2M
M6
E32-D11 2M
840
600
350
240
100
Square E32-D25XB
2M
240
170
100
60
30
Sensing
method
Heat-resistant temperature
Model
Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-high-
speed mode
Through-
beam
100 °C
E32-T51R 2M
1,600
1,100
800
560
225
150 °C
E32-T51 2M
2,800
2,000
1,500
1,000
400
200 °C
E32-T81R-S 2M
1,000
720
550
360
140
350 °C
E32-T61-S 2M
1,680
1,200
900
600
240
Reflective
100 °C
E32-D51R 2M
670
480
280
190
80
150 °C
E32-D51 2M
1,120
800
450
320
144
200 °C
E32-D81R-S 2M
420
300
180
120
54
300 °C
E32-A08H2 2M
10 to 20
−
E32-A09H2 2M
20 to 30 (center 25)
−
350 °C
E32-D611-S 2M
420
300
180
120
54
E32-D61-S 2M
400 °C
E32-D73-S 2M
280
200
120
80
36
Sensing
method
Type
Sensing
width
Model
Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-high-
speed mode
Through-
beam
Area
11 mm
E32-T16PR 2M
3,100
2,200
1,700
1,120
440
E32-T16JR 2M
2,750
2,000
1,500
960
380
30 mm
E32-T16WR 2M
4,000
*
3,400
2,600
1,700
680
Reflective
Array
11 mm
E32-D36P1 2M
700
500
300
200
90
Sensing method
Tube
diameter
Feature
Model
Sensing distance (mm)
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-high-
speed mode
Tube-mounting
3.2/6.4/9.5 dia
Stable residual
quantity detection
E32-A01 5M
Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm,
Recommended wall thickness: 1 mm
8 to 10 dia
Mounting at
multi levels
E32-L25T 2M
Applicable tube: Transparent tube with a diameter of 8 to 10 mm,
Recommended wall thickness: 1 mm
No restrictions
Large tubes
E32-D36T 2M
Applicable tube: Transparent tube (no restrictions on diameter)
Liquid contact
(heat-resistant
up to 200 °C)
−
−
E32-D82F1 4M
Liquid-contact Type