E2EM

E2EM

2

Specifications

 Ratings/Characteristics

E2EM-X

j

X

j

 DC 2-wire Models

Item

E2EM-X4X

j

E2EM-X8X

j

E2EM-X16MX

j

E2EM-X15X

j

E2EM-X30MX

j

Size

M12

M18

M30

Type

Shielded

Shielded

Unshielded

Shielded

Unshielded

Sensing distance

4 mm 

±

10%

8 mm 

±

10%

16 mm 

±

10%

15 mm 

±

10%

30 mm 

±

10%

Setting distance (see note 1)

0 to 3.2 mm

0 to 6.4 mm

0 to 12.8 mm

0 to 12 mm

0 to 24 mm

Differential travel

15% max. of sensing distance

Sensing object

Ferrous metal (refer to 

Engineering Data for non-ferrous metal on page 4)

Standard object (mild steel)

12 x 12 x 1 mm

18 x 18 x 1 mm

45 x 45 x 1 mm

30 x 30 x 1 mm

70 x 70 x 1 mm

Response frequency (see note 2)

1 kHz

0.5 kHz

0.4 kHz

0.25 kHz

0.1 kHz

Power supply voltage (operating
voltage range)

12 to 24 VDC, ripple (p-p): 10% max., (10 to 30 VDC)

Leakage current

0.8 mA max.

Control output

Switching
capacity

5 to 100 mA

Residual
voltage (see
note 3)

5 V max. (under load current of 100 mA with cable length of 2 m)

Indicator

X1 models:

Operation indicator (red LED), operation set indicator (green LED)

X2 models:

Operation indicator (red LED)

Operation (with sensing object
approaching)

X1 models:

NO

X2 models:

NC

For details, refer to the timing charts on page 5.

Circuit protection

Surge absorber, load short-circuit protection

Ambient temperature

Operating: –25

°

C to 70

°

C (with no icing or condensation)

Storage: –40

°

C to 85

°

C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±

15% max. of sensing distance at 23

°

C in temperature range of –25

°

C to 70

°

C

Voltage influence

±

1% max. of sensing distance in rated voltage range 

±

15%

Insulation resistance

50 M

 min. (at 500 VDC) between current carry parts and case

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min between current carry parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 1,000 m/s

2

 for 10 times each in X, Y, and Z directions

Degree of protection

IEC60529 IP67

Connection method

Pre-wired models (standard length: 2 m)

Weight (packaged)

Approx. 60 g

Approx. 130 g

Approx. 150 g

Approx. 180 g

Approx. 210 g

Material

Case

Brass

a e a

Sensing
surface

PBT

Accessories

Instruction manual

Note:

1. Use within a range where the green indicator is lit. (Excluding the X2 models.)

2. The response frequency of the DC switch section is an average value. Use standard sensing objects, provide a distance of twice the

standard sensing object distance between sensing objects, and provide a setting distance of half the sensing distance as measure-
ment conditions.

3. Since the residual voltage is 5 V, confirm interface conditions with devices to be connected. Refer to page 11.

Summary of Contents for E2EM

Page 1: ...5 mm E2EM X15X1 see note E2EM X15X2 Unshielded M18 16 mm E2EM X16MX1 E2EM X16MX2 M30 30 mm E2EM X30MX1 E2EM X30MX2 Note Connector relay models cable length of 300 mm are available DC 3 wire Pre wired...

Page 2: ...temperature Operating 25 C to 70 C with no icing or condensation Storage 40 C to 85 C with no icing or condensation Ambient humidity Operating Storage 35 to 95 with no condensation Temperature influe...

Page 3: ...ensing distance at 23 C within temperature range of 40 C to 85 C 10 max of sensing distance at 23 C within temperature range of 25 C to 70 C 15 max of sensing distance at 23 C within temperature range...

Page 4: ...de length of sensing object d mm Mild steel Stainless steel SUS304 Copper Brass t 1 mm Side length of sensing object d mm Mild steel Stainless steel SUS304 Copper t 1 mm Side length of sensing object...

Page 5: ...zone Sensing object Proximity Sensor Rated sensing distance ON OFF Set indicator green ON OFF Operation indicator red Control output ON OFF Main circuit 0 V 0 V Brown Blue Load NC E2EM X4X2 E2EM X8X2...

Page 6: ...NO PNP open collector output E2EM X2B1 M1 E2EM X4B1 M1 E2EM X8B1 M1 E2EM X15B1 M1 Sensing object Control output Yes No ON OFF Operation indicator yellow ON OFF Main circuit Brown Black or Load 1 4 2...

Page 7: ...ion 0 3 mm2 insulator diameter 1 3 mm Standard length 2 m 2 X1 models Operation indicator red set indicator green X2 models Operation indicator red B C models Operation indicator yellow 42 dia Toothed...

Page 8: ...ulator diameter 1 9 mm Standard length 2 m 2 X1 models Operation indicator red set indicator green X2 models Operation indicator red 26 8 dia 1 1 Connector Models Shielded Mounting Hole Dimensions Out...

Page 9: ...17 max 30 18 dia 47 max 7 M5 x 32 M18 Y92E B30 45 0 2 17 max 50 30 dia 60 max 10 M5 x 50 M30 Note When using the Mounting Brackets for unshielded models pay attention to the influence of surrounding...

Page 10: ...the clearances given in the following table are maintained d dia Unit mm Type Item M8 M12 M18 M30 E2EM XjXj Shielded 2 4 3 6 6 XjXj DC 2 wire S e ded d 18 27 45 DC 2 wire D 2 4 3 6 6 m 12 24 45 n 18 2...

Page 11: ...ay be damaged or lose its water resistivity Do not tighten the nut with excessive force A washer must be used with the nut Shielded Model Unshielded Model Part B Part A Part B Part A Note The table be...

Page 12: ...at least a few times larger than the allowable power of the bleeder resistor iR Leakage current of the Proximity Sensor mA iOFF Load reset current mA It is recommended that 15 k max 450 mW min for 12...

Reviews: