E2EM
E2EM
5
Residual Voltage Characteristics
E2EM-X
j
X
j
Output residual voltage (V)
Load current (mA)
Operation
Output Circuits
E2EM-X
j
X
j
DC 2-wire Models
Opera-
tion
Model
Timing chart
Output circuit
NO
E2EM-X4X1
E2EM-X8X1
E2EM-X15X1
E2EM-X16MX1
E2EM-X30MX1
Non-sensing
zone
Unstable
sensing zone
Setting
position
Stable sensing
zone
Sensing
object
Proximity
Sensor
Rated sensing
distance
ON
OFF
Set indicator
(green)
ON
OFF
Operation
indicator
(red)
Control
output
ON
OFF
Main
circuit
(0 V)
0 V
Brown
Blue
Load
NC
E2EM-X4X2
E2EM-X8X2
E2EM-X15X2
E2EM-X16MX2
E2EM-X30MX2
Rated sensing
distance
Non-sensing zone
Sensing zone
Proximity
Sensor
ON
OFF
Control
output
Sensing
object
Operation
indicator
(red)
ON
OFF
Note:
1. The load can be connected to ei-
ther +V or 0 V line.
2. Since there is no polarity, there is
no need to pay attention to the
brown or blue polarity.