52
Removal
Pry the lock down with a flat-blade screwdriver and pivot the PC upward to
remove it.
Screwdriver
3-3-3 Connecting an Expansion Unit or Expansion I/O Unit
Up to 3 Expansion Units or Expansion I/O Units can be connected to a
CPM2A
CPU Unit. Use the following procedure when connecting an Expansion Unit or
Expansion I/O Unit.
1, 2, 3...
1. Remove the cover from the CPU Unit’s or the Expansion I/O Unit’s expan-
sion connector. Use a flat-blade screwdriver to remove the cover from the
Expansion I/O Connector.
Expansion
connector
cover
2. Insert the Expansion I/O Unit’s connecting cable into the CPU Unit’s or the
Expansion I/O Unit’s expansion connector.
Installing the CPM2A
Section 3-3