![Omron CPM2A - 11-2005 Manual Download Page 137](http://html1.mh-extra.com/html/omron/cpm2a-11-2005/cpm2a-11-2005_manual_742517137.webp)
4-2
Section
Programming Console Operations
119
4-2-29 Displaying the Cycle Time
This operation is used to display the current average cycle time (scan time).
It is possible only in RUN or MONITOR mode while the program is being
executed.
RUN
MONITOR
PROGRAM
OK
OK
No
1, 2, 3...
1. Press the CLR Key to bring up the initial display.
2. Press the MONTR Key to display the cycle time.
MONTR
00000SCAN TIME
012.1MS
“MS” in the display indicates
the unit “ms” for the cycle time.
There might be differences in displayed values when the MONTR Key is
pressed repeatedly. These differences are caused by changing execution
conditions.
4-2-30 Reading and Setting the Clock
This operation is used to read or set the CPU’s clock. The clock can be read in
any mode, but can be set in MONITOR or PROGRAM mode only.
Operation
RUN
MONITOR
PROGRAM
Read clock
OK
OK
OK
Set clock
No
OK
OK
1, 2, 3...
1. Press the CLR Key to bring up the initial display.
2. Press the FUN Key, SHIFT Key, and then the MONTR Key to display the
date and time.
FUN
SHIFT MONTR
TIM 99Ć02Ć22
11:04:32 MON(1)
3. Press the CHG Key to change the date and/or time.
CHG
TIM CHG? 9Ć02Ć22
11:04:32 MON(1)
The digit that can be changed will flash. If necessary, input a new value with
the Up and Down Arrow Keys or Numeric Keys. Press the CHG Key to move
the cursor to the next digit. The following table shows the setting ranges for
each value.
Year
Month
Day
Hour
Minute
Second
Day-of-week
00 to 99
01 to 12
01 to 31
00 to 23
00 to 59
00 to 59
0 to 6
(SUN to SAT)
4. Press the WRITE Key to write the new value.
WRITE
INST TBL READ
FUN018:HEX
Press the CLR Key to return to the initial display.