A-4 CP1L Programming Examples
140
SYSMAC CP1L Getting Started Guide
Ap
pend
ix
z
PLC Setup
Specify the settings for pulse output 0.
1.
Open the PLC Settings dialog box.
2.
Click the Pulse Output 0 tab.
3.
Set the following settings.
4.
Close the PLC Settings dialog box.
5.
To apply changes made to the PLC settings, turn the PLC power ON.
Base Settings
Origin Search
Item
Setting
Item
Setting
Undefined Origin
Hold
Use define origin operation
Use
Limit Input Signal Operation
Always
Search Direction
CW
Limit Input Signal
NO
Detection Method
Methd 0
Search/Return Initial Speed
0pps
Search Operation
Invers 1
Speed Curve
Trapezoidal
Operating Mode
Mode 1
Origin Input Signal
NO
Proximity Input Signal
NO
Search High Speed
10000pps
Search Proximity Speed
1000pps
Search Compensation Value
0
Search Acceleration Ratio
2000
Search Deceleration Ratio
2000
Positioning Monitor Time
0ms