![background image](http://html1.mh-extra.com/html/omron/c200he-cpu-z-series/c200he-cpu-z-series_installation-manual_742479156.webp)
Appendix B
Specifications
141
Terminal Connections
A0
A1
A2
A3
A4
A5
A6
A7
A8
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
COM (0 V)
1
3
5
7
9
11
NC
0
2
4
6
8
10
24 VDC
(0.3 A max )
L
L
L
L
L
L
L
L
L
L
L
L
+ 24 VDC
L
L
13
15
L
L
12
14
Note Be sure to supply power to B9; otherwise current will leak through the load while the output is OFF.
Transistor Output Unit C200H-OD213
Max. Switching Capacity
2.1 A 24 VDC
+10%
/
–15%
(5.2 A/Unit) NPN output
Min. Switching Capacity
None
Leakage Current
0.1 mA max.
Residual Voltage
1.4 V max.
ON Response Time
0.2 ms max.
OFF Response Time
0.3 ms max.
No. of Circuits
1 (8 points/common)
Internal Current Consumption
140 mA 5 VDC max.
Fuse Rating
8 A 125 V (5.2-dia.x20)
Power for External Supply
30 mA 24 VDC
+10%
/
–15%
min.
Weight
250 g max.
Dimensions
A-shape
Circuit Configuration
Internal
Circuit
L
OUT
COM
OUT
Output indicator
L
+ V
24 VDC
Fuse blowout
detection circuit
Fuse
F indicator
Fuse: UL-TSC-8A-N1 (Nagasawa)
8 A 125 V 5.2-dia
20
Note When the fuse blows, the F indicator lights and bit 08 turns ON. Bits 08 through 15 cannot be used as IR bits.