background image

Page 5

1) Configure DIP-switches

DIP-switches are located on the side of the module.  The DIP-switches are used to 

configure modes of operation and networking features. 

DIP-switch Bank Locations

The table below provides a description of each DIP-switch position and function for 

each model.  Factory default is the DOWN position.

10G/S

Switch

Position

Top

Legend

1 RJ-45 Models

2 RJ-45 Models

Function

SW1

DOWN

Normal

Reserved for future use

Normal Switch Enabled

UP

Directed

Directed Switch Enabled

SW2

DOWN

Off

Reserved for future use

Reserved for future use

UP

On

SW3

DOWN

Off

Reserved for future use

Reserved for future use

UP

On

SW4

DOWN

Off

Reserved for future use

Reserved for future use

UP

On

SW5

DOWN

Off

Reserved for future use

Reserved for future use

UP

On

SW6

DOWN

Off

Reserved for future use

Reserved for future use

UP

On

SW7

DOWN

Off

Reserved for future use

Reserved for future use

UP

On

SW8

DOWN

Off

Pause Disabled 

Pause Disabled 

UP

On

Pause Enabled

Pause Enabled

General Settings

MAC Learning Disabled

Mac Learning Enabled

L2CP Frames Tunneled

L2CP Frames Tunneled

DIP-switch Definitions

DIP-switches will vary depending on the port configuration of the media converter.  

Please refer to the table above for the port configuration.  

Page 6

SW1:  Mode Of Operation - “Normal / Directed”

This DIP-switch is only supported on models with 2 RJ-45 ports.

The module supports Normal Switch and Directed Switch mode.
The modes are described with MAC learning enabled.  When MAC learning is 

disabled, unicast packets are forwarded to all ports. 

Normal Switch Mode

When this DIP-switch is in the factory default DOWN “Normal” position, the module 

is configured for Switch Mode.  In this mode, the module operates as a standard 

layer 2 switch.  Data flow will follow MAC address mapping.

Directed Switch Mode (AKA Camera Mode)

When this DIP-switch is in the UP “Directed” position, the module is configured for 

Directed Switch Mode.  In this mode, traffic from all the RJ-45 ports is only forwarded 

to the uplink port P1, preventing broadcast traffic from flooding the other network 

ports.  Incoming traffic from uplink port P1 follows MAC address mapping.  

Directed Switch Mode

SW2 - SW7:  Reserved on all models

These DIP-switches must be left in the factory default DOWN position. 

SW8: Pause - “Off / On”

Setting the DIP-switch to the factory default DOWN “Off” position configures the 

module to advertise no Pause capability on all ports.  Setting this DIP-switch to the 

UP “On” position configures the module to advertise Symmetrical and Asymmetrical 

Pause capability to all ports.  

Summary of Contents for OmniConverter 10G

Page 1: ...ter can be extended to five 5 years by registering the product at www omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its optio...

Page 2: ...nter problems while installing this product contact Omnitron Technical Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 38 Tesla Irvine CA 92618 USA Email support om...

Page 3: ...media converter Please refer to the table above for the port configuration Page 6 SW1 Mode Of Operation Normal Directed This DIP switch is only supported on models with 2 RJ 45 ports The module suppor...

Page 4: ...040 08250 001x or 040 08251 001x for the proper installation guidelines Page 8 3 Apply Power AC Power Secure the ground wire to the ground screw See the figure below for the location of the grounding...

Page 5: ...s in the earthed circuit conductor between the DC source and the earthing electrode conductor WARNING Only a DC power source that complies with safety extra low voltage SELV requirements can be connec...

Page 6: ...ps 100Mbps 1Gbps 2 5Gbps 5Gbps and 10Gbps 5 Verify Operation Verify the module is operational by viewing the LED indicators Power LED Indicators Legend Indicator Description Pwr OFF Unit not powered G...

Page 7: ...Only 1 1 lbs 498 9 grams Module w Adapter 1 6 lbs 725 7 grams Operating Temperature Commercial 0 to 50 C Wide 40 to 60 C 20 C AC cold start Storage 40 to 80 C Humidity 5 to 95 non condensing Altitude...

Page 8: ...Mechanical Page 15 Page 16...

Reviews: