18.
Charging Management
47
www.sinetech.co.za
18.
Charging Management
Charging Parameter
Default
Value
Note
Charging current
60A
Software adjustable from 10Amps to
100Amps.
Floating charging voltage (default) 54.0 Vdc Software adjustable from 50Vdc to
60Vdc.
Max. absorption charging voltage
(default)
56.0 Vdc
Software adjustable from 50Vdc to
60Vdc.
Battery overcharge protection
62.0 Vdc
Charging process based on default
setting.
3 stages:
First
–
Charge voltage increases to
56V, at max current;
Second
- Charge voltage will
remain at 56V until charge current
drops below 12 Amp;
Third
- Float charging at 54V.
Bulk
Floating
Absorption
time
U
time
I
Bulk Voltage
Float Voltage
This inverter is compatible with sealed lead acid, vented, gel and lithium batteries.
Installation and maintenance details of these batteries are provided in the battery
manufacturer’s manu
al.