14.
Application with Energy Meter
23
www.sinetech.co.za
14.
Application with Energy Meter
With Modbus card II and energy meter, hybrid inverter can easily be integrated into an
existing household. For details please refer to Modbus card II manual.
Note:
This application is only valid for
Grid-Tie with Backup II
mode.
Equipped with Modbus card II, hybrid inverter is connected to energy meter with RS485
communication port. This enables control of self-consumption via Modbus card to control
power generation and battery charging.
Hybrid Inverter
Battery
Non-Critical
Load
RS-485
Energy Meter
Grid
L1
L2
L3
N
L
AC Output
PV Array
N
G
L
N
G
Critical
Load
Modbus Card