Ordering Guide
Model Number
SP-006-1-C-050G
Layer N pressure monitoring and control smart probe with discrete I/O -
50 psi 350 kPa Gauge
SP-006-1-C-050A
Layer N pressure monitoring and control smart probe with discrete I/O -
50 psi 350 kPa Absolute
SP-006-1-C-100G
Layer N pressure monitoring and control smart probe with discrete I/O -
100 psi 700 kPa Gauge
SP-006-1-C-250G
Layer N pressure monitoring and control smart probe with discrete I/O -
250 psi 1700 kPa Gauge
Notes:
•
Model Numbers above have a ¼ - 18 NPT male pressure port (i.e. ordering code C)
•
Inquire with Omega Engineering for other pressure port options. Refer to Figure 3.
4
Hardware Setup
4.1
Connecting your Layer N Smart Interface
The SP-006 requires a Layer N Smart Interface to connect to a computer. Omega offers a variety of Layer N Smart
Interfaces such as the wired IF-001 (USB) and IF-002 (Modbus) or the wireless IF-006. Use the M12 8-Pin Connector
diagram below to connect the SP-006 to a Layer N Smart Interface.
Pin
Name
Function
Pin 1
DIO 0
Discrete I/O Signal 0
Pin 2
INTR
Interrupt Signal
Pin 3
SCL
I2C Clock Signal
Pin 4
SDA
I2C Data Signal
Pin 5
Shield
Shield Ground
Pin 6
DIO 1
Discrete I/O Signal 1
Pin 7
GND
Power Ground
Pin 8
3.3VDD
Power Supply
Figure 4: M12 8-Pin
Connector front view