background image

How  to  Program  Remote Controls  to  the  Alarm

Step 1: Turn "On" the ignition.

Step 2: Within 7 seconds press the Valet Switch 5 times.  The alarm will chirp
the siren once to confirm entry into Remote Control Programming Mode.

Step 3: Within 10 seconds, press the “Arm” Button on each remote to be pro-
grammed.  The siren will chirp to confirm each time a remote has been pro-
gramed.

If 10 seconds expire without any programming activity, or if the ignition is turned
“Off”, the system will automatically exit Remote Control Programming Mode.
The siren will emit 2 long chirps to confirm exit.

NOTE: Up to 4 remote controls can be programed to operate the alarm. When-
ever a remote control, new or existing, is programmed to the alarm, all existing
codes are erased for security.  So, all remote controls which are to operate the
alarm must be programmed at the same time.

How  to  Program  Features

To access Features Programming Mode:

Step 1: Turn the ignition "On" then "Off".

Step 2: Within 10 seconds of turning the ignition "Off", press the Valet Switch 5
times. The siren will chirp once confirming entry to Features Programming Mode.

Step 3: Within 10 seconds of entering Features Programming Mode, press the
Valet Switch the number of times equal to the number of the feature to be pro-
grammed.  The siren will repeat the feature number with chirps to confirm.

Step 4: After the system acknowledges the feature to be programmed:

Press the transmitter button that corresponds to the desired setting.

Note: Once the feature to be programed is selected,  you can toggle the
feature between its settings by pressing the “Arm”, “Disarm” & “••”
buttons on the remote control.

- To program more features, simply repeat Steps 3 and 4.
- If 10 seconds expire without any programming activity, or if the ignition is turned
“On”, the alarm will automatically exit Features Programming Mode. The siren
will confirm exit.

Page 7

Summary of Contents for MC-1

Page 1: ...MC 1 Motocycle Personal Craft Security System Operation and Installation Guide c 2009 Omega Research Development Inc...

Page 2: ...his device must accept any interference received includinginterferencethatmaycauseundesiredoperation The manufacturer is not responsible for any radio or TV interferencecausedbyunauthorizedmodificatio...

Page 3: ...ights will flash once The LED Status Indicator will begin to flash slowly The starter interrupt will engage The alarm is now fully armed Once it is disarmed it will not automatically arm again This fe...

Page 4: ...med Activated Regardless of the method used to Arm the alarm once Armed the alarm will monitor all protected zones and if an intrusion attempt is detected it will activate or trigger A trigger consist...

Page 5: ...ivated if the vehicle s ignition is On ThissecuritysystemisequippedwithadualstageDigitalTiltSensortoincrease it seffectiveness Eachtimethealarmisarmed thetiltsensorentersa5second learning period in wh...

Page 6: ...s The siren will emit a 2 long chirps to endicate it has exited the sensitivity adjustment mode The parking lights will flash twice Or the horn will sound if connected TheLEDStatusIndicatorvisuallysho...

Page 7: ...n use Valet Mode can only be entered into while the alarm is Disarmed ValetModeisdesignedforsituationsinwhichitisnotconvenientfortheautomatic armingandautomaticrearmingportionofthealarmtobeoperational...

Page 8: ...med at the same time How to Program Features To access Features Programming Mode Step 1 Turn the ignition On then Off Step 2 Within 10 seconds of turning the ignition Off press the Valet Switch 5 time...

Page 9: ...en arming and disarming Pressingthe Arm buttonmakesthesirendurationsettoMedium pressingthe Disarm buttonmakesthesirendurationsettotheLowestsetting andpressing the button extends the time to the Highes...

Page 10: ...these is the case In either case the included fuse holder and a 15 amp fuse must be used The fuse holders should always be close to the power source connection not the control module Remove the 15 amp...

Page 11: ...rm is triggered SIREN CONNECTION The Brown wire may be connected directly to the siren s Red wire and the siren s Black wire is connected to Ground SIRENMOUNTING Findalocationawayfromtheextremeheatoft...

Page 12: ...tional output operated by the remotes button CONNECTION If the target wire is Positive switching and or draws more than 250mA an optional relay must be used To configure a relay to the Pink wire conne...

Page 13: ...Page 12...