4
PART 2
HARDWARE
2.1 Mounting
2.1.1 Mounting the Wall Mount iServer
Position unit where required. Mark and drill the two #6 screw holes.
After bracket is mounted on the wall, align back of unit over the three bracket clips,
once engaged, slide downward, the unit will snap in place.
Figure 2.1 Mounting - Wall Mount iServer
It is recommended that you ground your unit. With one end of a wire
connected to earth ground, the other side can be wraped around the ground
screw, located on the bottom of the case.
If unit is to be mounted on a flat surface, you may take the bottom rubber
feet off the unit.
For overall dimensions of unit, refer to
Figure 5.1
in Specifications Section.
2.60 [66.0]
1.30 [33.0]
3.67 [93.1]
1.50 [38.1]
1.07 [27.3]
Bracket Clips (3)
Drill 0.14 [3.6] (2 plcs)
Use #6 Screws (Provided)
to Mount the Bracket
Ethernet
Ground Screw
on Rear of Case