23 |
M 5 7 9 1
6.4
How to Retrieve Logged Data
After a date range is set, click Retrieve Data to download the logged data as a .CSV file. If changes
are made to the logging interval, click Update to finalize the changes.
The log interval can be configured to change the frequency that data is logged. Data will be logged
into the internal 11 GB memory. Some Smart Probes come with more than one active sensor.
These sensors can be individually enabled or disabled using Omega’s SYNC configuration
software. The log interval can be configured to adjust the lifespan of the internal memory capacity
according to this table:
6.5
Events and Notifications Configuration
The Events and Notifications window of the iServer 2 web UI allows users to configure alarm
thresholds, triggers, and notification parameters. The following table describes the available alarm
triggers.
Alarm Trigger
Description
System Error
Notifies the user when there is a probe fault.
Battery Level Warning
Notifies the user when the iServer 2 battery power is running
low.
TTL Contact Activation
Notifies the user when a Contact Closure alarm has been
triggered.
Probe Disconnection
Notifies the user when a probe has been disconnected from
the iServer 2.
Out of Memory
Notifies the user when the internal iServer 2 memory is full.
Power Reset
Notifies the user when a power reset has occurred.
Sample Rate
2 Active
Sensors
4 Active
Sensors
1 second
(max)
4 years
2 years
5 seconds
24 years
12 years
10 seconds
40 years
20 years