16 |
P a g e
7.3.7.2
Verbose
The Verbose mode causes expanded information when using the IF-006 in the CLI mode.
7.3.7.3
Hex
The Hex mode causes the data to be displayed as HEX values in the CLI mode.
7.3.7.4
CLI Enable
The CLI enable bit enables the CLI command interpreter.
7.3.7.5
Force Enumeration
If set, the enumeration process will be re-applied to the probe.
7.3.7.6
Device Reset
Setting the Device Reset bit will force the device to re-initialize using the current configuration information.
7.3.7.7
Factory Reset
Setting the Factory Reset bit will force a factory reset and all configuration parameters will be returned to
the initial factory default values.
7.3.7.8
Shutdown
The MSP processor advises the radio subsystem when power is too low to continue operation thru the
Reset Pending status bit. After appropriate processing by the radio subsystem it should set the
Shutdown bit in the control register which will force the MSP processor to shut down the sensor
interface.
Failure to generate the Shutdown command may lead to unstable operation as the measured battery
voltage continues to degrade.
7.3.7.9
Reset Stats
The Reset Stats bit will force the I2C Statistic counters to be reset to 0.
7.3.7.10
Boot Mode
Setting the Boot Mode bit forces the devices into a boot strap mode. Once entered the device only
accepts bootstrap records allowing firmware upgrades. The Boot Mode flag always reads back as 0.
7.3.7.11
Authentication Required
If set, Probe Authentication is applied when probes are enumerated.