SPECIFICATIONS - TURBINE
All data for
A109GMA025NA1 and A109GMA100NA1
determined with 1 centipoise
Kermac solvent test fluid at 70° F (21° C). Data for FTB385 is determined with water at 70°
F (21° C).
9
Models
A109GMA100NA1
A109GMA200NA2
Size
A109GMA025NA1
1 inch Low Flow
1 inch
2 inch
Linear Flow Range
Gallons/minute (GPM)
0.3-3
3-50
30-300
Litres/minute (LPM)
1-11
11-190
114-1,135
Maximum Flow
Gallons/minute (GPM)
3
50
300
Litres/minute (LPM)
11
190
1,135
Maximum Pressure Drop
in 10:1 Range
PSIG
8
5
4
bar
0.55
0.34
0.28
Frequency Range in
11-110 Hz @ 36.5-608.3 Hz @ 36-360 Hz @
Flow Range
0.3-3 GPM
3-50 GPM 30-300 GPM
Connections
NPT
Yes
Yes
Yes
Female
Yes
Yes
Yes
Inlet/Outlet Size
1 in.
1 in.
2 in.
Weight with Computer
Electronics
Pounds
1.35 lbs.
1.35 lbs.
3.0 lbs.
Kilograms
.61 kg
.61 kg
1.36 kg
Performance
Linear Range for 1 in. Low Flow: N/A*
Linear Range for 1 in.:
± 1.5% of reading
Linear Range for 2 in.:
± 1.5% of reading
Repeatability for 1 in. Low Flow: ± 1%
Repeatability for 1 in.:
± 0.2%
Repeatability for 2 in.:
± 0.2%
Pressure Rating
300 PSIG (21 bar)
Wetted Components
Housing:
Aluminum
Journal Bearings:
Ceramic (96% Alumina)
Shaft:
Tungsten Carbide
Rotor and Supports:
Nylon
Retaining Rings:
316 Stainless Steel
Temperature Range
-40° F to +250°F (-40° C to +121° C)
These temperatures apply to operations and storage. They are only for the
turbine without computer electronics. Final operational temperature range is
determined by computer electronics or accessory modules.
* Accuracy can vary up to ±5% depending on installation and fluid type. Field calibration is recommended
for best accuracy.