CONVENIENCE
SECURITY
INST
ALLER ONL
Y
User Feature Programming: Ignition on, off, press valet 5 times
# Feature
Lock Button
(Brake 1x)
Unlock button
(Brake 2x)
Trunk button
(Brake 3x)
Start button
(Brake 4x)
Lock +
Unlock
(Brake 5x)
Trunk
+ Start
(Brake 6x)
1 Remote Start Run Time
3 min
10 min
15 min
20 min
30 min
2 Flashing Light Confirmations
Unlock: ON
RS: ON
Unlock: ON
RS: Flash
Unlock: Flash
RS: ON
Unlock: Flash
RS: Flash
3 Confirmation Chirp Volume
Low
Med-Low
Med-High
High
4 BROWN Wire: Siren/Pulsed Horn
Pulse LOW
Pulse MED
Pulse HI
Steady Siren
Random
5 Ignition Lock / Unlock
Off
Ign On = Lock
Ign. Off = Unlock Lock + Unlock
6 Door Open Bypass for Feat. #5
On*
Off
7 Unlock w/ Trunk Release
On
Off
8 RS Activation (Remote)
Start x 1
Start x 2
Start x 3
Start x 4
9 Last Door Arming
Off
On w/o Lock*
On w/ Lock*
10 Automatic Rearming
Off
On w/o Lock
On w/ Lock
Enhanced
11 Confirmation Chirps
Siren + Horn
Siren Only
Horn Only
On Demand
Off
12 Anti-Carjacking
Ignition
Door*
Ig Door*
Off
13 Override Code
See operation guide for programming instructions. DEFAULT: 1,0
14 Ignition Override
On
Off
15 Alarm Trigger Duration
30 sec
60 sec
90 sec
120 sec
16 Arming Delay
3 sec
15 sec
30 sec
45 sec
17 Open Door Warn Upon Arming
On
Off
Installer Feature Programming: Ignition on, off, press valet 10 times
1 RS Activation
(WHITE/BLUE wire)
1 Pulse
2 pulses
3 pulses
4 pulses
2 Vehicle Learn
Enabled
Disabled
3 Engine Detection
Prog. Voltage
Voltage
Tach Wire
Data-tach
Crank Only
4 Gasoline or Diesel Engine
Gasoline
15 sec Diesel
20 sec Diesel
30 sec Diesel
5 Sat. Port GREEN Wire
Dome Light
Start
Ignition
Accessory
Status
Light Flash
6 Sat. Port BLUE Wire
Ignition
Status
0.8 sec Defrost
Pulse
10 min Defrost
Pulse
Pulse After
Engine Off
Horn
7 Crank Time
0.75 sec
1 sec
1.5 sec
2.25 sec
3 sec
Average
8 Door Lock/Unlock Outputs
0.8 sec
3 sec
Double Unlock
Total Closure
9 Remote Start Lock Control
Off
Lock after Start Unlock before
Start
Unlock Before
& Lock After
Lock After
Engine Off
10 Turbo Timer
Off
1 min
2 min
3 min
11 Manual Trans. Reservation
On
Off
12 Data Port Protocol
Green: DBI
Black: DBI
Green: iData
Black: iData
Green: DBI
Black: iData
Green: iData
Black: DBI
13 Alarm Functions
On
Off
Off-Unlock Only
Sensor Detect
14 Pulse Ign. on Disarm
On
Off
15 Lock On Prewarn
On
Off
16 Starter Interrupt
Alarm Only
Anti-grind Only
Alarm/Anti-Grind Automatic
17 Low Temp Crank Extender
0 ms
200 ms
300 ms
400 ms
18 OEM Arm/Disarm or CH. 4/5
Arm/Disarm
Arm/CH5 Pulse CH4 Pulse/
Disarm
CH4 Pulse/
CH5 Pulse
CH4 Latch/
Disarm
CH4 Latch/
CH5 Pulse
19 BROWN Wire
Horn
Ignition
Trunk Release
Pulse After
Start
20 Low Current Mode
On
Off
FEATURE SETTING KEY:
Default Setting
Installer Feature 13 (Alarm Functions) must be ON
* Door status required from external interface module or DATA sensor w/ analog inputs.