background image

 

 

CL3515R K/J/T/E/R/S/N/L/U/B/C Calibrator Thermometer 

2. Calibrate Out   

Adjust output in real time. 

 

Value

   

Set the output vale. 

Send   

Press

 “

Send” CL3515R send out the output setting vale. 

 

3. Auto Send 

 

Group Item 

Group 0 to Group 9. 

Step Item Send 

Step Item 0 to Step Item 9. 

Forward 

Select step forward. 

Backward 

Select step backward. 

12 

 

 

CL3515R K/J/T/E/R/S/N/L/U/B/C Calibrator Thermometer 

1. Power button “

 

The “ ” button turns the thermometer on or off. When entering REC mode, the 
power off function is disabled. 
 

Remark: The meter will run self calibration when the meter starts. 

The measuring leads and calibration wires must be removed before 
taking measurements, and you can get accurate calibration values. 

 

2. Button “°C/°F/°K” 

Press the °C/°F/°K button to cycle through temperature scale, °C, °F and °K. 
 

3. Type Selection (thermocouples) 

Press the “type” button and the selected symbol will blink which means in the setting 
mode. 
Press “

” button to make right shifts to cycle through 

K

J

T

E

R

S

N

L

U

B

C

mV. 

Press “

” button to make left shifts to cycle through 

K

mV

C

B

U

L

N

S

R

E

T

J. 

Press the “type” button again to choose the selected thermocouple. 
 

4. Backlight “ ” button 

Pressing the button less than two seconds to turn on and pressing the button again less 
than two seconds to turn off the backlight in the LCD. It will turn off after thirty 
minutes without operation. 

Auto power off 

It is in the APO mode when the meter is turned on and will turn off the meter without 
operation for fifteen minutes. Pressing the “ ” button over two seconds to cancel the 
function. And pressing the “ ” button again to activate the APO function. 
 

5. “REL” button   

The relative value function can be used for comparing the saved reference value with 
other measurements. Press the “REL” button less than to store the current 
measurement as the reference value, and press the “REL” over two seconds to disable 
the function. 
 

6. “HOLD” button     

When HOLD mode is selected, the thermometer holds the present readings and stops 
all further measurements. To activate the data hold mode, press the HOLD button, 
and “HOLD” is displayed on the LCD. Pressing the HOLD button again cancels the 
function, and the instrument will automatically resume measurements. When the Hold 
key is activated, it will stop functions of the other entire key except Power and 
Backlight. 

 

Summary of Contents for CL3515R

Page 1: ...CL3515R K J T E R S N L U B C Calibrator Thermometer e mail info omega com For latest product manuals www omegamanual info Shop online at omega comSM User sGuide ...

Page 2: ...USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide omega com info omega com The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice ...

Page 3: ...ensor The thermometer features a dual thermocouple input an adjustable T C offset The thermocouples types comply with the N I S T Monograph 175 Revised to ITS 90 standard SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the thermometer WARNING To avoid electrical shock do not use this instrument when working voltages at the measurement surface o...

Page 4: ...Hz to1000MHz the measurement number producing the unsteady flutter it immediately recover after stop the test Accessories Two type K thermocouple bead wires Two type K thermocouple calibration bead wires Maximum insulation temperature 260 C 500 F Wire accuracy 2 2 C or 0 75 of reading whichever is greater from 0 C to 800 C A 9 volts battery An instruction manual Pc connection software Pc interface...

Page 5: ...5 rdg 2 0 F 58 F to 346 F N TYPE 0 05 rdg 1 0 C 50 C to 0 C 0 05 rdg 0 5 C 0 C to 1300 C 0 05 rdg 2 0 F 58 F to 32 F 0 05 rdg 1 0 F 32 F to 2372 F R S B C TYPE 0 05 rdg 2 C 0 C to 1767 C 0 05 rdg 4 F 32 F to 3212 F 3 K TYPE 0 1 200 C to 1372 C or 328 F to 2501 F J TYPE 0 1 210 C to 1200 C or 346 F to 2192 F T TYPE 0 1 250 C to 400 C or 418 F to 752 F E TYPE 0 1 250 C to 1000 C or 418 F to1832 F R ...

Page 6: ...ion 10uV Accuracy 0 025 1 digit Temperature Coefficient 0 1 times the applicable accuracy specification per C from 0 C to 18 and 28 C to 50 C 32 F to 64 F and 82 F to 122 F Top Side 1 Output 1 2 Output 2 3 Input T1 4 Input T2 5 RS232 optical interface OPERATING INSTRUCTIONS 4 4 2 1 3 5 CL3515R CL3515R K J T E R S N L U B C Calibrator Thermometer 4 Record Export Both Display drawing T1 and T2 T1 Di...

Page 7: ...L N S R E T J Press the type button again to choose the selected thermocouple 4 Backlight button Pressing the button less than two seconds to turn on and pressing the button again less than two seconds to turn off the backlight in the LCD It will turn off after thirty minutes without operation Auto power off It is in the APO mode when the meter is turned on and will turn off the meter without oper...

Page 8: ...its a tone when a new minimum or maximum measurement is recorded Press the MIN MAX button again to rotate through the current readings MAX The highest measurement recorded MIN The lowest measurement recorded MAX MIN The difference of the highest and the lowest measurement AVG The average values of the measurements Press MIN MAX button over two seconds to exit the function 10 Knob usages in the set...

Page 9: ...al shock disconnect the thermocouple connectors from the thermometer before removing the cover MAINTENANCE Battery Replacement Power is supplied by a 9 volt battery NEDA 1604 IEC 6F22 The appears on the LCD display when replacement is needed To replace the battery remove the two screws from the back of the meter and lift off the battery cover Remove the battery from battery contacts Cleaning Perio...

Page 10: ... L U B C Calibrator Thermometer I CL3515R Software Install Click Next Click Next 8 CL3515R K J T E R S N L U B C Calibrator Thermometer Click Next Click Finish II Uninstall StarÆsettingÆcontrolÆnew remove programÆCL3515R 9 ...

Page 11: ... L U B C Calibrator Thermometer I CL3515R Software Install Click Next Click Next 8 CL3515R K J T E R S N L U B C Calibrator Thermometer Click Next Click Finish II Uninstall StarÆsettingÆcontrolÆnew remove programÆCL3515R 9 ...

Page 12: ...al shock disconnect the thermocouple connectors from the thermometer before removing the cover MAINTENANCE Battery Replacement Power is supplied by a 9 volt battery NEDA 1604 IEC 6F22 The appears on the LCD display when replacement is needed To replace the battery remove the two screws from the back of the meter and lift off the battery cover Remove the battery from battery contacts Cleaning Perio...

Page 13: ...its a tone when a new minimum or maximum measurement is recorded Press the MIN MAX button again to rotate through the current readings MAX The highest measurement recorded MIN The lowest measurement recorded MAX MIN The difference of the highest and the lowest measurement AVG The average values of the measurements Press MIN MAX button over two seconds to exit the function 10 Knob usages in the set...

Page 14: ...L N S R E T J Press the type button again to choose the selected thermocouple 4 Backlight button Pressing the button less than two seconds to turn on and pressing the button again less than two seconds to turn off the backlight in the LCD It will turn off after thirty minutes without operation Auto power off It is in the APO mode when the meter is turned on and will turn off the meter without oper...

Page 15: ...ion 10uV Accuracy 0 025 1 digit Temperature Coefficient 0 1 times the applicable accuracy specification per C from 0 C to 18 and 28 C to 50 C 32 F to 64 F and 82 F to 122 F Top Side 1 Output 1 2 Output 2 3 Input T1 4 Input T2 5 RS232 optical interface OPERATING INSTRUCTIONS 4 4 2 1 3 5 CL3515R CL3515R K J T E R S N L U B C Calibrator Thermometer 4 Record Export Both Display drawing T1 and T2 T1 Di...

Page 16: ...r 418 F to 752 F E TYPE 0 1 250 C to 1000 C or 418 F to1832 F R TYPE 1 0 C to 1767 C or 32 F to 3212 F S TYPE 1 0 C to 1767 C or 32 F to 3212 F N TYPE 0 1 200 C to 1300 C or 328 F to 2372 F L TYPE 0 1 200 C to 900 C or 328 F to 1652 F U TYPE 0 1 200 C to 600 C or 328 F to 1112 F B TYPE 1 600 C to 1820 C or 1112 F to 3308 F C TYPE 1 0 C to 2316 C or 32 F to 4200 F Based on the ITS 90 temperature st...

Page 17: ...Hz to1000MHz the measurement number producing the unsteady flutter it immediately recover after stop the test Accessories Two type K thermocouple bead wires Two type K thermocouple calibration bead wires Maximum insulation temperature 260 C 500 F Wire accuracy 2 2 C or 0 75 of reading whichever is greater from 0 C to 800 C A 9 volts battery An instruction manual Pc connection software Pc interface...

Page 18: ...ensor The thermometer features a dual thermocouple input an adjustable T C offset The thermocouples types comply with the N I S T Monograph 175 Revised to ITS 90 standard SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the thermometer WARNING To avoid electrical shock do not use this instrument when working voltages at the measurement surface o...

Page 19: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans...

Page 20: ...ewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industrial pH Conductivity Equipment DATA ACQUISITION M U Data Acquisition Engineering Software M U Communications Based Acquisition Systems M U Plug in Cards for Apple IBM Compatibles M U Data Logging Systems M U Reco...