background image

RLV431

      69-2073EF-1                    2008-01-29                    1/4

RLV431

User Guide

Programmable Thermostat

The RLV431 thermostat can be used to control an electric heating
system such as a baseboard heater, a radiant floor, a radiant ceiling,
a convector, a fan-forced heater, etc.

The thermostat cannot be used with the following:

a resistive load under 2 A

a resistive load over 12.5 A

systems driven by a contactor or a relay (inductive load)

central heating systems

SUPPLIED PARTS

One (1) thermostat

Two (2) 6-32 mounting screws

Two (2) solderless connectors

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.

All cables and connections must comply with local electrical
codes.

This thermostat has tinned copper wires for line and load con-
nections. Special CO/ALR solderless connectors must be used if
these wires will be connected to aluminum conductors.

Install the thermostat onto an electrical box.

Install the thermostat about 5 feet high, on an inside wall facing
the heater.

Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a
door), or direct sunlight. 

Do not install the thermostat on a wall that conceals chimney or
stove pipes.

The thermostat wires are not polarized; either wire can be con-
nected to the load or to the power supply.

n

Connect the thermostat using solderless connectors for copper 
wires.

o

Secure the thermostat to the electrical box using the provided 
screws. Insert the screws through either the right or left pair of 
mounting holes on the thermostat.

p

If there is a protective film or sticker on the thermostat’s screen, 
peel it off.

q

Apply power to the heating system.

r

Verify the installation by checking that the heater can be turned 
On and Off by raising and lowering the setpoint using the 

Up

 and 

Down

 buttons.

WARNING: Keep the thermostat's air vents clean and free from
obstructions.

n

Description

1.

Period no. in 
Automatic mode

Temperature

Heating power 
indicator

Time and day

Manual 
mode

Automatic 
mode

Economy 
mode

Setting no. in 
Economy mode

Appears during 
a power failure

Appears when the 
setpoint is displayed

Flashes when the 
clock has been reset

Appears if the 
thermostat is configured 
for a fan-forced heater

Display

NOTE:

To access the programming keypad, remove the cover by placing 

your fingers to the right edge of the thermostat and pulling it.

Up/Down buttons

Mode button

Day button

Hour button

Program button

Return button

Reset opening

Minute button

o

Installation

2.

120/240
Vca

120/240
Vca

Solderless connector 
for copper wires

Electric baseboard

2-wire installation

4-wire installation

Solderless connector 
for copper wires

Electric baseboard

400-102-002-B_69-2073EF-1 (Honeywell RLV431) ENG.fm  Page 1  Tuesday, January 29, 2008  10:12 AM

Summary of Contents for RLV431

Page 1: ...o the load or to the power supply n Connect the thermostat using solderless connectors for copper wires o Secure the thermostat to the electrical box using the provided screws Insert the screws through either the right or left pair of mounting holes on the thermostat p If there is a protective film or sticker on the thermostat s screen peel it off q Apply power to the heating system r Verify the i...

Page 2: ...tomatic programmable mode To use the Automatic mode press the Mode button until Auto is selected outlined on the screen The cur rent period number will appear In this mode the thermostat automatically adjust its temperature setpoint according to the period of the day wake up leave for work return home and sleep You can program up to 4 periods in a day You can set 2 different programs one for the w...

Page 3: ...gm button During a power outage the thermostat display remains lit for approx imately the next 15 minutes during which the LP low power indica tor appears The settings are stored in memory However if the power failure exceeds 5 hours only the thermostat s clock must be re adjusted When power returns the thermostat returns to the mode of operation preceding the power outage Period Temperature Setti...

Page 4: ... the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the prod uct within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WAR RANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the...

Page 5: ...corder les fils du thermostat en utilisant des connecteurs sans soudure pour fils de cuivre o Fixer le thermostat à la boîte électrique à l aide des vis fournies Passer les vis dans l une des deux paires de trous de fixation droite ou gauche p Enlever la pellicule autocollant de l écran s il y en a une q Mettre le système de chauffage sous tension r Vérifier l installation en s assurant que le sys...

Page 6: ...et Min pour régler l heure q Appuyer sur le bouton Ret pour terminer Le thermostat a trois modes de fonctionnement Mode automatique programmable Pour placer le thermostat en mode automatique appuyer sur le bouton Mode jusqu à ce que la mention Auto soit sélectionnée encadrée à l écran Dans ce mode le thermostat change automatiquement de réglage de température selon la période de la journée réveil ...

Page 7: ...Enlever le trombone lorsque l affichage dispar aît de l écran q Attendre une seconde et relâcher le bouton Pgm Lors d une panne de courant la mention LP s affiche pendant les 15 premières minutes Ensuite l écran s éteint Les réglages sont sauve gardés en mémoire Cependant si la panne dépasse 5 heures seule l horloge du thermostat devra être rajustée Le thermostat retournera au mode de fonctionneme...

Page 8: ...it conformément aux modalités susmentionnées HONEYWELL N EST EN AUCUN CAS RESPONSABLE DES PERTES OU DOMMAGES Y COMPRIS LES DOMMAGES INDIRECTS OU ACCESSOIRES DÉCOULANT DIRECTEMENT OU INDIRECTEMENT D UNE VIOLATION QUELCONQUE D UNE GARANTIE EXPRESSE OU TACITE APPLICABLE AU PRÉSENT PRODUIT NI DE TOUTE AUTRE DÉFECTUOSITÉ DU PRÉSENT PRODUIT Certaines provinces ne permettent pas l exclusion ou la restric...