OMAX JetMachining® Center Operator’s Guide
Maintenance
4 - 18
400433D-EN
check to see if the orifice assembly is still seated in the bore). Refer to Figure 4-32 for an example of an
orifice that had been tightened several times while off-center and not correctly seated in its bore.
Figure 4-32: Damage Caused by an Off-center Orifice
5.
Place the
spanner wrench
onto the
brass retaining nut
at the top of the
nozzle body
and a
1/2"
box end wrench
on the upper hex of the
inlet body
and tighten the
brass retainer nut
.
Figure 4-33: Tightening the Nozzle’s Brass Retainer Nut
6.
Remove the
spanner wrench
and use the
1/2" box end wrench
to hold the
inlet body
in place to
counteract any torque when tightening the
nozzle body
. Using a
1" open-end wrench
placed on
the
nozzle body
, turn slowly clockwise to tighten the
nozzle body
to the
inlet body
.
Figure 4-34: Tightening the Nozzle Body to the Inlet Body
7.
Tighten the
nozzle body
to approximately 30 - 40 ft lbs (40.7 - 54.2 Nm).
spanner wrench
1/2" box end
brass retaining nut
1/2" box end
nozzle inlet body
nozzle body
1" open-end