DMTA029-01EN, Rev. E, December 2017
Chapter 4
54
Wet locations
Yes
Pollution level
2
Waterproof
Yes
Venturi vacuum generator (optional)
Venturi generator
Manufacturer: Pisco
Manufacturer’s part number: VKMH12B-S692NS2-B02
Air pressure, flow, and holding force: see Table 4 on page 54
Air input connector
Quick-coupling male nipple, 1/4 NPT
Table 4 Venturi vacuum generator specifications (VKMH12B
‑
S692NS2
‑
B02)
Parameter
Minimum
value
Maximum
value
Input air supply pressure
MPa (psi)
0.35 (50.8)
0.5 (72.5)
Final vacuum
−
kPa (
−
inHg)
73 (21.6)
93 (27.6)
Suction flow
NL/min (SCFM)
36 (1.26)
38 (1.33)
Air consumption
NL/min (SCFM)
47 (1.64)
70 (2.45)
Horizontal mounting holding force per 102 mm
(4 in.) OD suction cup (safety factor = 4)
kg (lb)
15.0 (33)
18.2 (40)
Vertical mounting holding force per 102 mm (4 in.)
OD suction cup (safety factor = 8)
kg (lb)
7.5 (16.5)
9.1 (20)
Table 3 General specifications
(continued)
Parameter
Value