Service Manual
683311W
4-39
4.6.5 MEASURING THE LENGTH OF THE DOCUMENT
The form length measurement is necessary for a quick management of the passbooks' magnetic
stripe. By selecting the "STRIPE HANDLING: FAST" setup item the value read by the form
measurement procedure will be used to determine the position of the magnetic stripe and to position
the stripe itself above the magnetic head, without the need to making an additional passbook
measurements. In this way there is considerable time saving in passbook management. For this
feature to work correctly, the same passbooks measured must be used.
Proceed as follows to make this adjustment:
1. Power on the printer with its cover open and while holding down the three console keys.
2. Wait for an acoustic signal to indicate that the printer has switched into the adjustment mode and
close the cover.
3. Press the "Station 2" key.
4. After this phase only the "Station 1" will be active and can be used to start form length reading.
5. Insert an A4 sheet of paper in the insertion slot and press the "Station 1" key. The sheet will be
automatically inserted and ejected.
6. Repeat step 5 if necessary.
7. Press the "Local" key to permanently store the form length value measured and to move on to the
next adjustment.