8. Undo the screws (6) fixing the Video-Touch Screen unit to its support frame.
9. Rotate the unit and disconnect the signal cables of the Video (7) and the Touch Screen (8).
8
3-12
Service Manual
Y117850-4
Figure 3-21
During the reassembly phase make sure that the earth faston is connected correctly with
the metal shield of the Video-Touch Screen unit.
Figure 3-22
After replacing the Video-Touch Screen unit, you must always calibrate the Touch Screen
using the Diagnostic Tool “DiagNettuna7000I 1.00.04.0.2” or later versions.
For reassembly follow the same procedure in reverse order paying particular attention to the warnings
indicated.