Field Service Ver. 3.0 Jan. 200
12
. Malfunction code
97
FS-519/PK-515/OT
-602
T
roubleshooting
12
.2
Solution
12
.2.1
C1004: FNS communication error
12
.2.2
C1183: Elevator motor ascent/descent drive failure
Relevant electrical parts
FS control board (FSCB)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical
component)
1
Disconnect and then connect the power
cord. Turn OFF the main power switch, wait
for 10 sec. or more, and turn ON the main
power switch.
—
—
2
Rewrite firmware using the compact flash
card.
—
—
3
Change FSCB
—
—
Relevant electrical parts
Elevator motor (M11)
Elevator tray home position sensor (PS11)
Elevator tray lower limit sensor (PS13)
Elevator top face detection sensor (PS12)
Relay board/1 (REYB/1)
FS control board (FSCB)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical
component)
1
Check the M11 connector for proper con-
nection and correct as necessary.
—
—
2
Check M11 for proper drive coupling and
correct as necessary.
—
—
3
If OT-602 is connected, check the con-
nector for proper connection, and correct
as necessary.
—
—
4
Check the installation position of the OT-
602 tray, and correct as necessary.
—
—
5
M11 operation check
FSCB PJ6-5 to 6
FS-519 J-4
6
PS11 I/O check, sensor check
FSCB PJ18-6 (ON)
FS-519 L-3
7
PS13 I/O check, sensor check
FSCB PJ18-3 (ON)
FS-519 L-4
8
PS12 I/O check, sensor check
FSCB PJ18-4 (ON)
FS-519 L-3
9
Change REYB/1
—
—
10
Change FSCB
—
—
Y10
8442-7
Service Manual