Field Service Ver.
3
.0 Jan. 2008
3
. Periodical check
1
7
FS-519/PK-510/OT
-602
Maintenance
5.
To reinstall, reverse the order of
removal.
NOTE
• Before attaching a new cleaning
pad, clean the metal surface where
the new cleaning pad is attached.
• Align the right ends of the new
cleaning pad and the metal as
shown in the illustration.
3
.1.3
Lubricating the worm gear and replacing the cover film
A. Periodically lubricated parts/cycle
• Worm gear: Every 800,000 prints
B. Periodically replaced parts/cycle
• Cover film: Every 800,000 prints
C. Procedure
NOTE
• Before the following lubrication and replacement work, make sure to remove
optional SD-505 and MT-502 when the finisher is equipped with these options.
1.
Turn the main and sub power switch ON. Then turn the main power switch OFF when
the tray reaches the lowest position during the initial operation.
2.
Remove the tray unit rear cover.
See P.
29
3.
Remove the wire saddle [1] and dis-
connect the connector [2].
A01GF2C551DA
+-
+
-
A01GF2C559DA
[1]
[2]
Y10
8442-7