Field Service Ver. 2.0 Dec. 2008
7. Soft Switch
77
FK-507
Adjustment / Setting
NOTE
• The features with (*) are settable by users. <*>: Soft switch setting
• Some machines cannot receive calls.
Care must be taken when you set the ringing count to 10 or more.
• For PSTN1, refer to MODE 520.
MODE
Factory setting bit
212 (PSTN1)
232 (PSTN2)
Bit:
7
6
5
4
3
2
1
0
0
1
0
0
0
0
0
0
HEX: 40 (For U.S.)
HEX: 00 (For Europe)
Bit
Feature
Logic
Description
0
1
7
DP make rate
Bit 7-6:
00
33 %
Specify the DP signal
make ratio.
6
01
40 %
Others
Not available
MODE
Factory setting bit
249
Bit:
7
6
5
4
3
2
1
0
0
0
0
0
1
0
0
0
HEX: 08
Bit
Feature
Logic
Description
0
1
7
Specify the ringing count
of auto receiving call
(PSTN2) <*>
Bit 7-3:
00000
0
Specify the PSTN2 ring-
ing detection count. The
ringing count is the num-
ber of rings until the
machine automatically
starts receiving a call.
6
00001
1
5
|
4
10100
20
3
Others
Not available
MODE
Factory setting bit
288
Bit:
7
6
5
4
3
2
1
0
1
1
1
1
1
1
1
1
HEX: FF
Bit
Feature
Logic
Description
0
1
7
Insert dummy data before
PIX.
Bit 7-0:
00000000 Add 200 ms
• Specify period to
transmit dummy data
before transmitting
PIX.
• Add the period speci-
fied here to the first
flag (EMC) and FILL
(G3) of the image sig-
nal.
6
00000001 Add 300 ms
(200 ms +
100 ms)
5
4
3
00000011 Add 900 ms
(200 ms +700
ms)
2
1
0
11111111 Add 200 ms
Others
Not available
Y109971-7 Sevice Manual