Test Run
By completing the steps in the previous sections, the sander is ready for a test run.
1.
Before connecting the sander to a power source, press the “OFF” button on the power switch to
prevent the machine from starting unintentionally.
2.
Make sure the platen is locked into position.
3.
Tighten the lock knobs of the belt guard, the dust chute, and the table.
4.
Check belt tension. Move the belt to ensure it is not catching the guard and other stationary parts.
5.
Connect the machine to power.
6.
Turn on the machine. The sanding belt should oscillate and track within the platen. If the sanding belt
is not tracking properly,
TURN OFF MACHINE IMMEDIATELY.
See section “Inspect / Adjust Belt
7.
Allow the machine to run for a minute. During the initial run, a small amount of loose graphite may
fall off from the platen. That is part of the break-in process and it is expected.
8.
Turn off the sander to complete the test run.
Congratulations for completing the test run! If you discover any issues from the tests, refer to the
troubleshooting section and maintenance section to diagnose issues and make adjustments.
Summary of Contents for 6303
Page 7: ...6303 Sander OLIVERMACHINERY NET 7 Page Identification...
Page 37: ...6303 Sander OLIVERMACHINERY NET 37 Page Wiring Diagrams...
Page 38: ...38 Page Oliver Machinery 6303 Sander Parts List Table and Base...
Page 39: ...6303 Sander OLIVERMACHINERY NET 39 Page Stand...
Page 40: ...40 Page Oliver Machinery 6303 Sander Motor and Sander Assembly...
Page 41: ...6303 Sander OLIVERMACHINERY NET 41 Page Idler Drum...
Page 46: ...46 Page Oliver Machinery 6303 Sander Maintenance Record Date Task Operator...
Page 47: ...6303 Sander OLIVERMACHINERY NET 47 Page Notes...
Page 49: ......