SHERPA AQUADUE TOWER
Z2
Z1
Z3
EN - 37
ENGLISH
The screen is divided into three
zones:
Z1. Activation status of the components connected to the board of the internal unit (red on indicates
active status):
•
pump
:
Main circulation pump
•
DHW
pump
:
DHW domestic hot water circulation pump
•
Heater 1
:
Heater 1 (Electric heater EH1)
•
Heater 2
:
Heater 2 (Electric heater EH2)
•
DHW
3way valve
: 3-way valve
•
DHW ext heater
: DHW domestic hot water accumulation electric heater
•
DHW comp
:
DHW domestic hot water high temperature circuit compressor (only for AQUADUE models)
•
Ext boiler
:
Boiler (Activation of external source of heat)
•
Alarm
:
Alarm
•
Pump speed
:
Main circuit water pump speed
The outputs can be modified from the display if the heat pump is in stand-by mode, otherwise they are
in read only mode.
Z2. Visualization of the temperatures measured by the internal unit probes:
•
T1 water in
:
system water return temperature
•
T2 water out
:
system water delivery temperature
•
T3 DHW tank
:
domestic hot water reservoir temperature
•
T4 outdoor air
: external air temperature, only if applicable
•
T5 DHW comp
: DHW domestic hot water high temperature circuit compressor delivery temperature (only
for AQUADUE models)
•
T6 DHW cond
:
domestic hot water condenser temperature (only for AQUADUE models)
•
T7 DHW evap
:
domestic hot water evaporator temperature (only for AQUADUE models)
•
T8 solar system
: inlet temperature from solar thermal circuit, only if applicable
Z3. Visualization of the internal unit inputs (red on indicates active status):
•
FL1 water flow
: main water circuit flow switch
•
FL2 DHW flow
: domestic hot water evaporator circuit flow switch
•
COOLING ON
:
cooling mode command (terminal 1 of power board, short with L for activation)
•
HEATING ON
:
heating mode command (terminal 2 of power board, short with L for activation)
•
ECO
:
desired temperature energy saving command (terminal 3 of power board, short with L for
activation)
•
NIGHT
:
night function command (terminal 4 of power board, short with L for activation)
•
DHW
:
request for domestic hot water from external contact (terminal 6 of power board, short with
L for activation)
•
TA
:
cooling and heating enabling command (terminal 7 of power board, short with L for activa-
tion)
•
FTV1
:
input from photovoltaic or smart grid system (terminal 8 of power board, short with L for
activation)
•
FTV2
:
input from photovoltaic or smart grid system (terminal 9 of power board, short with L for
activation)
•
CO%
:
IN / OUT shows IN capacity (supplied by the external unit) and OUT capacity (requested
to the external unit)
Summary of Contents for Sherpa AQUADUE S3 E
Page 2: ......
Page 6: ...3 1 2 S P X P...
Page 7: ...4 1 10 2 6 5 3 4 11 17 18 19 D 16 8 13 14 15 6 B 20 A 7 13 12 9 C E...
Page 9: ...6 7 6b 6a 25 V V1 V1 26 S Q Q Q Q X2 C1 K4 K3 K2 K1 X3 X1...
Page 10: ...9 60 s C 6 3 4 5 2 1 8 U1 U2 8 10 12 14 16 kW 4 6 kW 10a 10b U4 U3 U3 U4...
Page 16: ...21 22...
Page 315: ......
Page 316: ...264400B...