2.4 - FIXED INSTALLATION
The air conditioner can also be installed with fixed holes in windows or walls. Air flow must not be obstructed
by protective mesh or similar. Any forms of protection must have a total cross-section for air flow of not less
than 140 cm
2
.
a.
Position the machine side terminal (2) on the flexible hose (1) as shown by Fig.8.
b.
Drill a 127 mm hole in the glass or in the wall at a height above the floor included between 300 and 1200
mm (Fig.13).
c.
Position the terminal (7) in the wall hole and mark the drilling points (Fig. 14-a, 14-b).
d.
Remove the terminal (7) and drill 6 mm holes (Fig. 14-c, 14-d).
e.
Insert the supplied wallplugs (10) in the holes (Fig. 14-e).
f.
Position the terminal
(7) in the hole of the wall and fix it with the supplied screws (10) (Fig. 14-f, 14-g).
g.
Insert the machine side terminal (2) on the air outlet grid of the appliance (36) as shown in figure 9.
h.
Connect the other extremity of the flexible hose (1) on the terminal (7)
(Fig.14-i).
i.
Close the cap (7a) when the appliance is not running (Fig.14-h).
2.5 - ELECTRICAL CONNECTION
The appliance is fitted with a power cable with plug.
Before connecting the air conditioner ensure that:
• The voltage and power frequency values match those specified on the
appliance plate data.
• The power line is equipped with an effective earth connection and is
correctly sized for maximum power consumption of the air conditioner.
• The appliance’s power network must be equipped with a suitable
omnipolar disconnection device compliant with national installation
regulations.
• The appliance is powered solely through a socket compatible with the plug provided.
CAUTION
Any replacement of the power cable must be carried out solely by Olimpia Splendid
technical support or by similarly qualified personnel.
2.6 - DRAINAGE
Depending on the modality of use of the appliance, it is necessary to connect the condensation discharge pipe.
2.6.a - Use as dehumidifier
For the correct use of the appliance, work as follows (figures 29 and 32):
a.
Remove the cap (28).
b.
Insert the supplied pipe (12) in the connector.
Make sure the end of the discharge pipe (12) is positioned on a drain well or in a container.
Make sure the pipe (12) is not clogged.
c.
If necessary, apply the terminal (13) to the condensation discharge pipe (12).
2.6.b - Use as heat pump
(only for the suitable version)
For the correct use of the appliance, work as follows (figures 30 and 33):
a.
Remove the cap (35).
b.
Insert the supplied pipe (12) in the connector.
Make sure the end of the discharge pipe (12) is positioned on a drain well or in a container.
Make sure the pipe (12) is not clogged.
c.
If necessary, apply the terminal (13) to the condensation discharge pipe (12).
Summary of Contents for DOLCECLIMA AIR PRO
Page 9: ...min 2m min 2m 2 1 3 3 2 36 4 4 6 8 10 7 9 11...
Page 11: ...27 27a 27 27 27 27a 27 27a 27 18 20 22 23 19 21...
Page 12: ...30 8m 32 32a 30 12 28 28 32 32a 24 28 26 25 29 27...
Page 13: ...32 35 35 30 31 15 27 27 27a 34 28 35 32 33 12 12...
Page 184: ...EL 2 0 0 1 0 2 0 2 1...
Page 189: ...DOLCECLIMA AIR PRO EL 7 15 16 17 18 19 20 21 22 a b c d e CO2 f g...
Page 190: ...EL 8 h I 23 a b 24 25...
Page 191: ...DOLCECLIMA AIR PRO EL 9 26 27 25 OFN 28 OFN OFN OFN OFN 29 OFN 30 a b c...
Page 192: ...EL 10 d e f g h 80 i j k 31 32...
Page 198: ...EL 16 3 3 TV 3 3 a a 15 b 15 c 18 3 3 b 1 5V AAA 15 3 3 c 24 8 28...
Page 206: ...EL 24 7 P1...
Page 376: ...UK 2 0 0 1 0 2 0 2 1...
Page 381: ...DOLCECLIMA AIR PRO UK 7 15 16 17 18 19 20 21 22 a b c d e CO2 f...
Page 382: ...UK 8 g h i 23 b 24...
Page 383: ...DOLCECLIMA AIR PRO UK 9 25 26 27 LFL 25 OFN 28 OFN OFN OFN OFN 29 OFN...
Page 384: ...UK 10 30 a b c d e f g h 80 i j k 31 32...
Page 390: ...UK 16 3 3 3 3 a a 15 b 15 c 18 3 3 b 1 5 V AAA 15 3 3 c 24 8 28...
Page 398: ...UK 24 7 P1 Error Code...
Page 424: ...265775B 1...