173
CrossFire 8600/8605 Token-Ring Switches v. 1.2, P/N: 710001641
Monitoring the Network with the Console
Max Message Age
Time at which the configuration message used by the spanning-tree algorithm
should be discarded. This time is advertised by the root and used by all devices and
switches in the active topology of the spanning-tree network.
Forward Delay
Time the root waits between transitions from listening to learning, and from
learning to forwarding. This time is advertised by the root and used by all devices
and switches in the active topology of the spanning-tree network.
CRF
VLAN ID of a TrCRF belonging to this TrBRF.
PId
Port ID that is used to determine the role of the port in the spanning tree. The port
ID is expressed in the form port priority.port number.
PCst
Cost associated with each port. Lower numbers are generally assigned to ports
attached to faster media (such as FDX or CrossLinks), and higher numbers are
generally assigned to ports attached to slower media.
PSts
Current status of this CRF within the spanning tree. Possible values are:
•
DIS (Disabled)
•
BLK (Blocked)
•
LSN (Listening)
•
LRN (Learning)
•
FWD (Forwarding)
The rules that define the state of the port are as follows:
•
A CRF that does not connect to other switches or bridges is always forwarding.
•
When the switch is booted, all CRFs are blocked initially, and then some of
them change to a different state: listening, learning, and forwarding, in that
order. All CRFs that are going to change states from blocking to forwarding
will have done so after two to three times the value of:
Switch Maximum Message Age + (2 x Switch Forward Delay)
Summary of Contents for CrossFire 8600
Page 1: ...DOC 6951 1 2 CrossFire TM 8600 8605 Guide to Operations Token Ring Switches...
Page 2: ......
Page 3: ...CrossFire TM 8600 8605 Token Ring Switches Guide to Operations...
Page 6: ...iv CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641...
Page 32: ...16 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Overview and Specifications...
Page 58: ...42 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Theory of Operation...
Page 160: ...144 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Switch Configuration...
Page 216: ...200 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Troubleshooting...
Page 226: ...210 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Abbreviations...
Page 236: ...220 CrossFire 8600 8605 Token Ring Switches v 1 2 P N 710001641 Cable and Pin Information...
Page 249: ......